首页> 外文期刊>Journal of Nanoelectronics and Optoelectronics >The Method for On-Line Monitoring of tan delta of Transformer Bushing Based on Conductor Temperature Distribution
【24h】

The Method for On-Line Monitoring of tan delta of Transformer Bushing Based on Conductor Temperature Distribution

机译:基于导体温度分布的变压器衬套Tan Delta在线监测方法

获取原文
获取原文并翻译 | 示例
           

摘要

On-line monitoring of dielectric loss factor of transformer bushing is of great significance to its safe and stable operation. However, on-line monitoring has problems of large disturbance and potential safety concerns. In this paper, a new method for on-line monitoring of dielectric loss factor of transformer bushing is proposed to overcome these problems. Optical fiber temperature measurement system is placed inside the conductor. According to relationship between the dielectric loss factor (tans) and conductor temperature distribution, the tans can be obtained by using finite element multi-physical field coupling method. This method is verified by the example of a 220 kV transformer bushing, and the error is less than 8%. This method is used to overcome the existing problems in on-line monitoring of dielectric loss factor.
机译:变压器衬套的介电损耗系数的在线监测对于安全和稳定的操作具有重要意义。 然而,在线监测存在大的干扰问题和潜在的安全问题。 本文提出了一种新的在线监测变压器衬套的介电损耗因子,以克服这些问题。 光纤温度测量系统放置在导体内。 根据介电损耗因子(棕褐色)和导体温度分布之间的关系,通过使用有限元多物理场耦合方法可以获得助剂。 通过220 kV变压器衬套的示例验证了该方法,误差小于8%。 该方法用于克服介电损耗因子的在线监测中存在的存在问题。