首页> 外文期刊>Journal of intensive care medicine >Quality Improvement Initiative to Reduce Pediatric Intensive Care Unit Noise Pollution With the Use of a Pediatric Delirium Bundle
【24h】

Quality Improvement Initiative to Reduce Pediatric Intensive Care Unit Noise Pollution With the Use of a Pediatric Delirium Bundle

机译:通过使用儿科谵妄捆绑,减少儿科重症监护单位噪声污染的质量改进措施

获取原文
获取原文并翻译 | 示例
           

摘要

Objectives: Noise pollution in pediatric intensive care units (PICU) contributes to poor sleep and may increase risk of developing delirium. The Environmental Protection Agency (EPA) recommends <45 decibels (dB) in hospital environments. The objectives are to assess the degree of PICU noise pollution, to develop a delirium bundle targeted at reducing noise, and to assess the effect of the bundle on nocturnal noise pollution. Methods: This is a QI initiative at an academic PICU. Thirty-five sound sensors were installed in patient bed spaces, hallways, and common areas. The pediatric delirium bundle was implemented in 8 pilot patients (40 patient ICU days) while 108 non-pilot patients received usual care over a 28-day period. Results: A total of 20,609 hourly dB readings were collected. Hourly minimum, average, and maximum dB of all occupied bed spaces demonstrated medians [interquartile range] of 48.0 [39.0-53.0], 52.8 [48.1-56.2] and 67.0 [63.5-70.5] dB, respectively. Bed spaces were louder during the day (10AM to 4PM) than at night (11PM to 5AM) (53.5 [49.0-56.8] vs. 51.3 [46.0-55.3] dB, P < 0.01). Pilot patient rooms were significantly quieter than non-pilot patient rooms at night (n=210, 45.3 [39.7-55.9]) vs. n=1841, 51.2 [46.9-54.8] dB, P < 0.01). The pilot rooms compliant with the bundle had the lowest hourly nighttime average dB (44.1 [38.5-55.5]). Conclusions: Substantial noise pollution exists in our PICU, and utilizing the pediatric delirium bundle led to a significant noise reduction that can be perceived as half the loudness with hourly nighttime average dB meeting the EPA standards when compliant with the bundle.
机译:目的:儿科重症监护单位(PICU)的噪音污染有助于睡眠不良,可能会增加发展谵妄的风险。环境保护局(EPA)建议在医院环境中提出<45分贝(DB)。目标是评估PICU噪声污染的程度,开发患有降低噪声的谵妄束,并评估束对夜间噪声污染的影响。方法:这是一个在学术PICU上的QI倡议。在患者床铺,走廊和公共区域安装了三十五个声音传感器。儿科谵妄捆绑在8名试点患者(40例患者ICU天)中实施,而108名未试点患者在28天内接受过常规护理。结果:收集了总共20,609个小时的DB读数。所有占用床铺的每小时最小,平均和最大dB都显示出48.0 [39.0-53.0],52.8 [48.1-56.2]和67.0 [63.5-70.5] DB的中位数[四分位数范围]。白天床铺更响亮(上午10点至下午4点)(晚上11点至下午5点)(53.5 [49.0-56.8],51.3 [46.0-55.3] DB,P <0.01)。试点患者房间比未经飞行员患者房间更安静(n = 210,45.3 [39.7-55.9])与N = 1841,51.2 [46.9-54.8] DB,P <0.01)。符合捆绑包的试验室具有最低的小时夜间平均DB(44.1 [38.5-55.5])。结论:我们的PICU存在大量噪音污染,利用儿科谵妄束导致显着的降噪,可以在符合捆绑包时与每小时夜间平均数据库进行一半的响度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号