首页> 外文期刊>Digestive and liver disease: official journal of the Italian Society of Gastroenterology and the Italian Association for the Study of the Liver >Accuracy of a new monoclonal stool antigen test in post-eradication assessment of Helicobacter pylori infection: comparison with the polyclonal stool antigen test and urea breath test.
【24h】

Accuracy of a new monoclonal stool antigen test in post-eradication assessment of Helicobacter pylori infection: comparison with the polyclonal stool antigen test and urea breath test.

机译:幽门螺杆菌感染后新型单克隆粪便抗原试验的准确性:与多克隆粪便抗原试验和尿素呼吸试验的比较。

获取原文
获取原文并翻译 | 示例
           

摘要

BACKGROUND AND AIM: The enzyme immunoassay based on polyclonal antibodies (HpSA) represents a valid method for the detection of Helicobacter pylori antigens in stool specimens, but some controversial results were reported in post-eradication setting. A new monoclonal enzyme immunoassay (FemtoLab H. pylori, Connex) has been developed. The present study compares the diagnostic accuracy of the two tests after eradication therapy. PATIENTS AND METHODS: Stool samples were collected and urea breath test and endoscopy performed in 325 patients (161 F, 164 M, age 17-78 years), 4-8 weeks after standard triple eradication therapy. The FemtoLab and HpSA tests were performed in accordance with the manufacturer's protocol. H. pylori infection was confirmed if culture alone or both urease test and histology were positive and was considered absent if all three tests were negative. RESULTS: H. pylori was eradicated in 231 patients (71.1%). Urea breath test showed the best performances with sensitivity 98.9% and specificity 99.5%. The sensitivity of FemtoLab was 88.3%, specificity 94.8%, positive and negative predictive values 87.4% and 95.2%. Corresponding HpSA values were 73.4%, 97.8%, 93.2% and 90%. Sensitivity and negative predictive value of FemtoLab were significantly better than HpSA. Adjusting the cut-offs according to a ROC curve improved not significantly the sensitivity of the two tests. CONCLUSIONS: Urea breath test shows the best accuracy in the assessment of H. pylori infection. Between the stool tests, the FemtoLab due to its higher sensitivity is to prefer in the post-eradication assessment of H. pylori infection.
机译:背景和目的:基于多克隆抗体(HPSA)的酶免疫测定代表了检测粪便标本中幽门螺杆菌抗原的有效方法,但在根除后的环境中报告了一些有争议的结果。已经开发出一种新的单克隆酶免疫测定(Femtolab H. Pylori,Connex)。本研究比较了根除治疗后两次测试的诊断准确性。患者和方法:收集粪便样品,并在325名患者中进行尿素呼气试验和内窥镜检查(161°F,164米,年龄17-78岁),在标准三重根除治疗后4-8周。 Femtolab和HPSA测试按照制造商的协议进行。如果单独的培养物或脲酶测试和组织学呈阳性,则确认幽门螺杆菌感染,并且如果所有三次测试都是阴性的,则认为缺乏。结果:H. Pylori在231名患者中删除(71.1%)。尿素呼气试验显示最佳性能,灵敏度为98.9%,特异性99.5%。 Femtolab的敏感性为88.3%,特异性为94.8%,正负预测值87.4%和95.2%。相应的HPSA值为73.4%,97.8%,93.2%和90%。 Femtolab的敏感性和负预测值明显优于HPSA。根据ROC曲线调整截止的改善,不显着提高两个测试的灵敏度。结论:尿素呼气试验显示了幽门螺杆菌感染评估的最佳准确性。在粪便测试之间,由于其较高的敏感性而导致的Femtolab是更愿意在根除幽门螺杆菌感染后进行消除后评估。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号