首页> 外文期刊>Journal of glaucoma >Diurnal Variation of Optical Coherence Tomography Measurements of Static and Dynamic Anterior Segment Parameters
【24h】

Diurnal Variation of Optical Coherence Tomography Measurements of Static and Dynamic Anterior Segment Parameters

机译:静态和动态前段参数光学相干断层扫描测量的昼夜变化

获取原文
获取原文并翻译 | 示例
       

摘要

Purpose:To examine the diurnal variation of static and dynamic anterior segment parameters in young, healthy eyes by comparing anterior segment optical coherence tomography (AS-OCT) measurements obtained in the morning and evening and also in the light and dark.Methods:Twenty-two subjects ranging from 19 to 47 years of age with no past ocular history were selected. Imaging was performed with the Tomey CASIA2 AS-OCT device in 2 fixed lighting environments, light and dark, between the hours of 08:30 to 10:00 and 17:30 to 19:00. Four AS-OCT images were analyzed per eye. Pupil diameter (PD), iris area (IA), iris curvature (IC), anterior chamber depth (ACD), lens vault (LV), anterior chamber width (ACW), anterior chamber area (ACA), angle opening distance (AOD), angle recess area (ARA), trabecular iris space area (TISA), and trabecular iris angle (TIA) were measured.Results:Pupil diameter was similar between the AM and PM groups in the light (P=0.89) and dark (P=0.51). There was no significant difference between AM and PM measurement values for any of the static or dynamic parameters in the light (P0.39) and dark (P0.31). Intraclass correlation coefficients (ICC) demonstrated excellent agreement between AM and PM measurement values in the light (ICC0.81) and dark (ICC0.93). In addition, there was no significant difference between AM and PM angle opening distance at 500 mu m measurement values in the light (P0.34) and dark (P0.40) when each of 8 angle sectors was analyzed individually.Conclusions:No significant diurnal variation of static or dynamic anterior segment parameter measurements was detected in the light and dark. Diurnal variation of these parameters does not regularly occur in young, healthy eyes.
机译:目的:通过比较早晚获得的前段光学相干性断层扫描(AS-OCT)测量,在清淡和黑暗中测量,检查年轻,健康的眼睛静态和动态前段参数的静态和动态段参数的昼夜变化。方法:二十 - 两个受试者从19至47岁的年龄范围内,没有选择过往眼睛历史。成像在2个固定的照明环境中,光线和黑暗,08:30至10:00至19:00之间的时间,在2个固定的照明环境中进行了成像。每只眼睛分析四个AS-OCT图像。瞳孔直径(PD),虹膜区域(IA),虹膜曲率(IC),前腔深度(ACD),透镜拱顶(LV),前腔宽度(ACW),前房面积(ACA),角度开口距离(AOD )测量角度凹陷区域(ARA),小梁虹膜空间区域(TISA)和小梁虹膜角度(TIA)。结果:光瞳直径在am和PM中的亮点之间相似(p = 0.89)和黑色( p = 0.51)。 AM和PM测量值之间的任何静态或动态参数之间没有显着差异(P> 0.39)和暗(P> 0.31)。脑内相关系数(ICC)在光(ICC> 0.81)和暗(ICC& 0.93)之间表现出AM和PM测量值之间的优异协议。此外,当单独分析8个角度扇区中的每一个时,AM和PM角度开口距离在500μm的测量值之间没有显着差异,在500μm的光(P> 0.34)和暗时(p> 0.40)。结论:无重大意义在光线和黑暗中检测到静态或动态段参数测量的昼夜变化。这些参数的昼夜变化在年轻,健康的眼睛中不经常发生。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号