首页> 外文期刊>Journal of chromatography, B. Analytical technologies in the biomedical and life sciences >Development and validation of an ultra-high performance liquid chromatography-tandem mass spectrometry method for the simultaneous determination of iohexol, p-aminohippuric acid and creatinine in porcine and broiler chicken plasma
【24h】

Development and validation of an ultra-high performance liquid chromatography-tandem mass spectrometry method for the simultaneous determination of iohexol, p-aminohippuric acid and creatinine in porcine and broiler chicken plasma

机译:超高效液相色谱 - 串联质谱法同时测定猪和肉鸡鸡血浆同时测定碘脂,P-氨基脲酸和肌酐的开发及验证

获取原文
获取原文并翻译 | 示例
       

摘要

In order to study the renal function, in terms of glomerular filtration and effective renal plasma flow, in broiler chickens and pigs, an ultra-high performance liquid chromatography-tandem mass spectrometry method for the simultaneous determination of iohexol, p-aminohippuric acid (PAH) and exogenously administered creatinine in plasma was developed and validated. Sample preparation consisted of a deproteinization step using methanol for porcine plasma and an Ostro (TM) Protein Precipitation & Phospholipid Removal Plate was used for broiler chicken plasma. Chromatographic separation was achieved on a Hypersil Gold aQ column using 0.1% formic acid in water and 0.1% formic acid in methanol as mobile phases. The total run time was limited to 10 min. Matrix-matched calibration curves for iohexol and PAH were prepared and good linearity (r >= 0.9973; gof <= 6.17%) was achieved over the concentration range tested (0.25-90 mu g/mL). Limits of quantification were 0.25 mu g/mL for iohexol and PAH. Water was used as surrogate matrix for analysis of creatinine in plasma. This surrogate calibration curve showed good linearity over the concentration range tested (0.25-90 mu g/mL) (r >= 0.9979; gof <= 5.66%). For creatinine, the relative lower limit of quantification was 201.03 +/- 49.20% and 60.14 +/- 7.64% for chicken and porcine plasma, respectively. The results for within-day and between-day precision and accuracy fell within the specified ranges.
机译:为了研究肾功能,就肾脏过滤和有效的肾脏等离子体流动,在肉鸡鸡和猪中,超高效液相色谱 - 串联质谱法,用于同时测定碘己醛,P-氨基脲酸(PAH )开发并验证了血浆中外源给药肌酐。样品制剂由使用甲醇用于猪等离子体的脱蛋白步骤,并且用于肌肉鸡等离子体使用汤酮(TM)蛋白沉淀和磷脂去除板。在Hypersil Gold AQ柱上使用0.1%甲酸在水中和0.1%甲酸作为移动相的甲酸中的色谱分离。总运行时间限制为10分钟。制备碘脂和PAH的基质匹配校准曲线,并在测试的浓度范围内(0.25-90μg/ ml)实现良好的线性度(r> = 0.9973; gof <= 6.17%)。碘醇和PAI的定量限制为0.25μg/ ml。水用作替代基质,用于分析血浆中肌酐。该替代校准曲线显示出测试的浓度范围(0.25-90μg/ ml)(r> = 0.9979; gof <= 5.66%)上的良好线性。对于肌酐,鸡肉和猪血浆的定量相对下限为201.03 +/- 49.20%和60.14 +/- 7.64%。在日内和白天的精度和精度之间的结果落在指定的范围内。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号