Reproducibility of laser in?situ keratomileusis flap thickness using a new multifunctional femtosecond laser platform and?correlation with clinical preoperative measurements

机译:使用新的多功能飞秒激光平台和临床术前测量的相关性的激光器的再现性。与临床术前测量的相关性

获取原文
获取原文并翻译 | 示例
           

摘要

PurposeTo analyze the reproducibility of laser in?situ keratomileusis (LASIK) flap thickness (target 120?μm) using the multifunctional femtosecond laser (Lensx) and correlate postsurgical measurements with preoperative factors. SettingHospital Oftalmológico Vis?o Laser, Santos, S?o Paulo, Brazil. DesignProspective case series. MethodsPatients with stable refraction for over a year were evaluated. Patients who submitted to refractive surgery with ?1.25 to ?6.00 diopters (D), with or without astigmatism up to ?4.00 D, and corneal curvature of 40.00 to 47.00 D were included. At 100?days postoperatively, an independent examiner performed 4 high-resolution tomographic sections of the cornea for each eye at 45- to 225-degree, 90- to 270-degree, 135- to 315-degree, and 0- to 180-degree meridians. Two masked experienced observers analyzed each section using measuring points located at the center of the cornea (0.0?mm), 2.0?mm to the left and to the right of the center, and 4.0?mm to the left and to the right of the center. ResultsThe study comprised 33 patients (63 eyes), aged 21 to 50?years. A significant difference from the target flap thickness (120?μm) was found in 2 of 20 measurements; however, the actual difference was approximately 2.2?μm. Interrater reliability was excellent (ICC?>?0.75), with an interrater bias close to 0. Clinical measurements were not predictive of the set of 20 postoperative measurements. ConclusionReproducibility of the multifunctional femtosecond laser was good for LASIK flap creation and no predictive correlation was found with preoperative clinical factors.
机译:Puposeto使用多功能飞秒激光(Lensx)分析激光的再现性(LASIK)襟翼厚度(靶120?μm),并通过术前因素与后勤测量进行相关。 Serventhospitaloftalmológicovis?o laser,santos,s?o paulo,巴西。 DesignProspective Case系列。评估折射率稳定折射的方法。提交屈光手术的患者?1.25至?6.00屈光度(D),有或没有像散到Δ.4.00d的散光,并且包括40.00至47.00d的角膜曲率。在术后100?几天,一个独立的检查员在45至225度,90至270度,135至315度,0到180度,对角膜进行4个高分辨率断层切片。学位经络。使用位于角膜中心(0.0≤mm)的测量点,将每个部分分析两个蒙面的经验型观察者,左侧和右侧的左侧和右侧4.0?mm中央。结果患者组成33名患者(63只眼),年龄21至50岁?年。从靶翼叶厚度(120μm)有显着差异在20次测量中的2个中发现;但是,实际差异约为2.2ΩΩμm。 Interriter可靠性优异(ICC?> 0.75),Internarder Bias接近0.临床测量不是预测到的20个术后测量。结论多功能飞秒激光的可生产性适用于LASIK皮瓣创造,并且没有发现术前临床因素的预测相关性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号