Purpose: To assess the clinical outcomes after continuous intracorneal ring (ICR) implantation for the management of keratoconus using femtosecond laser technology. Setting: Farabi Eye Hospital, Tehran University of Medical Sciences, Tehran, Iran. Design: Prospective nonrandomized consecutive case series. Methods: All patients presented with reduced visual acuity, contact lens intolerance, and a central corneal thickness of more than 360 μm. A Myoring ICR was inserted in an intrastromal pocket created by a femtosecond laser. The visual, refractive, aberrometric, and corneal biomechanical outcomes were measured preoperatively as well as 1, 3, and 6 months and 1 year postoperatively. Results: The study comprised 98 keratoconic eyes of 98 patients with a mean age of 30.7 years ± 9.01 (SD). Fifteen eyes (15.3%) had grade I keratoconus, 37 eyes (37.7%) had grade II keratoconus, 24 eyes (24.5%) had grade III keratoconus, and 22 eyes (22.4%) had grade IV keratoconus. The uncorrected and corrected distance visual acuities and spherical and cylindrical errors improved 1 month after surgery (P<.001); however, no changes were detected thereafter (P>.05). The mean keratometry and corneal astigmatism decreased 1 month after surgery (P<.001); however, no significant change was observed at the 3-month or 1-year visits compared with the 1-month values (P>.05). Primary coma decreased significantly (P=.03), and spherical aberrations increased significantly (P<.001) postoperatively. Conclusion: Continuous ICR implantation in keratoconus appears to be an acceptable substitute for keratoplasty in advanced keratoconus. Financial Disclosure: No author has a financial or proprietary interest in any material or method mentioned.
机译:目的:利用飞秒激光技术评估连续脑内环(ICR)植入后的临床结果。环境:法拉兰医科院法拉比眼医院,伊朗德黑兰医学院大学。设计:前瞻性非修复连续案例系列。方法:所有患者均呈现出可视敏锐度降低,隐形眼镜不耐受,中央角膜厚度超过360μm。迈出的ICR被插入由飞秒激光器产生的内部口袋。视觉,屈光,变形和角膜生物力学结果术前和术后1,3和6个月和1年。结果:该研究包括98名患者的98个角振振来,平均年龄为30.7岁±9.01(SD)。十五只眼(15.3%)患有I级角蛋白,37只眼(37.7%),24只眼(24.5%)患有III级角蛋白,22只眼(22.4%)具有IV级角蛋白。手术后1个月的未校正和校正的距离视力和球形和圆柱误差改善(P <.001);但是,此后未检测到更改(p> .05)。手术后1个月(P <.001)均下降1个月的平均触手法和角膜散光;但是,与1个月值相比,在3个月或1年访问中没有观察到重大变化(P> .05)。主要彗形昏迷显着降低(P = .03),球面像差显着增加(P <.001)。结论:在KeratoConus中的连续ICR植入似乎是高级角蛋白的角膜术替代品。财务披露:没有作者对提到的任何材料或方法都有财务或专有权益。

著录项

  • 来源
  • 作者单位

    Ophthalmology Research Center Tehran University of Medical Sciences Farabi Eye Hospital Ghazvin;

    Ophthalmology Research Center Tehran University of Medical Sciences Farabi Eye Hospital Ghazvin;

    Ophthalmology Research Center Tehran University of Medical Sciences Farabi Eye Hospital Ghazvin;

    Ophthalmology Research Center Tehran University of Medical Sciences Farabi Eye Hospital Ghazvin;

    Ophthalmology Research Center Tehran University of Medical Sciences Farabi Eye Hospital Ghazvin;

    Cornea Service Department of Ophthalmology Jules Stein Eye Institute Los Angeles CA United;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 眼科学;
  • 关键词

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号