To examine the effect of cavitation on the vibration of a multi-stage pump, a five-stage diffuser centrifugal pump was selected to test the vibration characteristics under non-cavitation and cavitation conditions. Vibrations were monitored at six points (V1-V6). Results show that when cavitation occurs, the vibration characteristic frequencies of the six measuring points obviously increase, for 1.0Q(d) (the design flow rate). The gap in the vibration velocity amplitude between the higher axial frequency harmonics and the main frequency becomes smaller, and the cavitation-induced vibration excitation is very obvious in all directions. When the flow rate is 0.8Q(d), peak values at the main vibration frequencies of the measuring points V1, V2 and V4 increase compared to those at 1.0Q(d). Vibration intensities when the flow rate is 1.2Q(d) are larger than at 0.8Qd, and vibration intensities at 1.0Q(d) are the lowest of the three. At 0.8Q(d) and 1.2Q(d), the maximum vibration intensities of the pump are 2.01 mm/s and 2.47 mm/s respectively, which is an increase of 87.85% and 111.11%, respectively.
机译:为了检查空化对多级泵的振动的影响,选择了一种五级扩散器离心泵,以测试非空化和空化条件下的振动特性。在六点(V1-V6)中监测振动。结果表明,当空化时,六个测量点的振动特性频率明显增加,为1.0q(d)(设计流速)。较高轴向频率谐波与主频率之间的振动速度幅度的间隙变小,并且空化诱导的振动激发在所有方向上非常明显。当流速为0.8q(d)时,与1.0q(d)的相比,测量点V1,V2和V4的主振动频率的峰值增加。当流速为1.2Q(d)时的振动强度大于0.8qd,1.0q(d)的振动强度是三个中最低的。在0.8Q(d)和1.2q(d)时,泵的最大振动强度分别为2.01 mm / s和2.47 mm / s,分别增加了87.85%和111.11%。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号