首页> 外文期刊>Journal of biomedical materials research. Part B, Applied biomaterials. >Cumulative effect of disinfection procedures on microhardness and tridimensional stability of a poly(methyl methacrylate) denture base resin.
【24h】

Cumulative effect of disinfection procedures on microhardness and tridimensional stability of a poly(methyl methacrylate) denture base resin.

机译:消毒程序对多(甲基丙烯酸甲酯)牙本质底树脂的微硬度和三维稳定性的累积作用。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Microwave irradiation has been used for disinfection of dentures instead of chemical solutions; yet, its effect on resin properties after repeated procedures still is unclear. This study evaluated the cumulative effect of two disinfection methods on Knoop microhardness and tridimensional stability of a poly(methyl methacrylate) denture base resin. For the microhardness measurement, 24-resin discs received mechanical polishing and were submitted to the following treatments: (1) control (no disinfection), (2) chemical disinfection (immersion in 100ppm chloride solution for 24h), or (3) microwave disinfection (irradiation at 690 W for 6 min). Disinfection procedures were performed twice (T1, T2) with a 7-day interval. Knoop microhardness was recorded after polishing (T0) and after T1 and T2. For the dimensional stability test (measured by the adaptation of the denture bases), 36-maxillary denture bases were obtained from type III dental stone casts duplicated from a metallic master model and submitted to the disinfection treatment. Adaptation of denture bases was measured at baseline (T0) and after T1 and T2 by weighing a vinyl polysiloxane film reproducing the gap between resin base and master model. Data were analyzed by ANOVA GLM for repeated measures and Bonferroni's test, alpha = 0.05. Knoop microhardness was not modified by any disinfection procedure but decreased over time. Denture resin bases submitted to microwave disinfection had gradual increase of distortion over time, while bases immersed in chloride solution did not differ from the control group and remained dimensionally stable from T1 to T2.
机译:微波辐射已被用于消毒伪造代替化学溶液;然而,它对重复手术后对树脂性质的影响尚不清楚。该研究评估了两种消毒方法对Poly(甲基丙烯酸甲酯)牙本质底树脂的持久性稳定性的累积作用。对于微硬度测量,24树树脂盘接收机械抛光,并提交到以下处理:(1)对照(无消毒),(2)化学消毒(浸入100ppm氯化物溶液24h),或(3)微波消毒(690 W处照射6分钟)。用7天间隔进行两次消毒程序两次(T1,T2)。在抛光(T0)和T1和T2之后记录Knoop显微硬度。对于尺寸稳定性测试(通过义齿碱的适应测量),从金属母模型重复的III型牙科石材铸件获得36-上颌义齿底座,并提交给消毒处理。通过称量乙烯基聚硅氧烷膜再现树脂基础和母模型之间的间隙,在基线(T0)和T1和T2之后测量义齿碱的适应。通过ANOVA GLM分析数据,用于重复措施和Bonferroni的测试,alpha = 0.05。 Knoop微硬度未被任何消毒程序修饰,但随着时间的推移降低。提交给微波消毒的义齿树脂碱随时间逐渐增加失真,而浸入氯化物溶液中的碱与对照组没有不同,并且从T1至T2保持尺寸稳定。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号