Adequate cleaning of reusable medical devices is critical for preventing cross-infection among patients. For reusable medical devices, cleaning using mechanical brushes and detergent may not be sufficient to completely remove the infectious contaminants from the surfaces. This study evaluates the role of fluid flow-induced shear stress in the detachment and removal of contaminants from device surfaces. A stainless-steel test coupon, acting as a surrogate for a device surface, was coated with artificial clot of varying mass. The test coupon was exposed to fluid shear stress both with and without an enzymatic detergent. The relationship between clot removal quantity and the applied shear stress was obtained for multiple clot masses. Our results showed that fluid shear increased the effectiveness of the cleaning process. In the absence of flow, soaking the clot surface in the enzymatic detergent removed 67%, 77%, and 95% of the clot for 16 mg, 6.8 mg, and 1 mg initial masses, respectively. In the presence of fluid shear (0.3 Pa for 5 min), approximately 85%, 97%, and 99% of the clot was removed from the surface. The clot mass removed followed a linear relationship (R-2 = 0.98) versus the applied fluid shear stress. This study showed that different cleaning processes such as fluid shear and detergent action contribute to the soil removal process. This method could be used to evaluate cleaning protocols for minimizing contaminant residue after the reprocessing of medical devices. (c) 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 107B: 1132-1140, 2019.
机译:可重复使用的医疗设备充分清洁对于预防患者之间的交叉感染至关重要。对于可重复使用的医疗设备,使用机械刷和洗涤剂的清洁可能不足以完全除去来自表面的传染性污染物。该研究评估了流体流动诱导的剪切应力在从装置表面脱离和去除污染物中的作用。一种不锈钢测试优惠券,用作器件表面的替代物,涂有不同质量的人工凝块。测试优惠吨在没有酶促洗涤剂的情况下暴露于流体剪切应力。为多个凝块质量获得凝块去除量和施加的剪切应力之间的关系。我们的研究结果表明,液体剪切提高了清洁过程的有效性。在没有流动的情况下,浸泡酶洗涤剂中的凝块表面除去67%,77%和95%的凝块,分别为16mg,6.8mg和1mg初始质量。在液体剪切(0.3Pa持续5分钟)的存在下,从表面中除去约85%,97%和99%的凝块。除去的凝块质量遵循线性关系(R-2 = 0.98)与施加的流体剪切应力。该研究表明,不同的清洁方法如流体剪切和洗涤剂作用有助于土壤去除过程。该方法可用于评估清洁方案以在再处理医疗器械后最小化污染物残留物。 (c)2018 Wiley期刊,Inc .J生物保解率A型B:苹果生物检索物107B:2019年1132-1140,2019。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号