...
首页> 外文期刊>Journal of Biomechanics >Flow instability detected in ruptured versus unruptured cerebral aneurysms at the internal carotid artery
【24h】

Flow instability detected in ruptured versus unruptured cerebral aneurysms at the internal carotid artery

机译:在内部颈动脉内发生破裂的流动性检测到的流动不稳定性

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Flow instability has emerged as a new hemodynamic metric hypothesized to have potential value in assessing the rupture risk of cerebral aneurysms. However, diverse findings have been reported in the literature. In the present study, high-resolution hemodynamic simulations were performed retrospectively on 35 aneurysms (10 ruptured & 25 unruptured) located at the internal carotid artery (ICA). Simulated hemodynamic parameters were statistically compared between the ruptured and unruptured aneurysms, with emphasis on examining the correlation of flow instability with the status of aneurysm rupture. Pronounced flow instability was detected in 20% (2 out of 10) of the ruptured aneurysms, whereas in 44% (11 out of 25) of the unruptured aneurysms. Statistically, the flow instability metric (quantified by the temporally and spatially averaged fluctuating kinetic energy over the aneurysm sac) did not differ significantly between the ruptured and unruptured aneurysms. In contrast, low wall shear stress area (LSA) and pressure loss coefficient (PLC) exhibited significant correlations with the status of aneurysm rupture. In conclusion, the present study suggests that the presence of flow instability may not correlate closely with the status of aneurysm rupture, at least for ICA aneurysms. On the other hand, the retrospective nature of the study and the small sample size may have to some extent compromised the reliability of the conclusion, and therefore large-scale prospective studies would be needed to further address the issue. (C) 2018 Elsevier Ltd. All rights reserved.
机译:流动不稳定性已成为一个新的血流动力学指标假设,以具有评估脑动脉瘤破裂风险的潜在价值。然而,文献中报道了各种调查结果。在本研究中,高分辨率血流动力学模拟在颈动脉(ICA)的35个动脉瘤(10个破裂和25个未破裂)上进行回顾性地进行。模拟血液动力学参数在破裂和未破裂的动脉瘤之间进行了统计学,重点是检查流动不稳定性与动脉瘤破裂状态的相关性。在破裂的动脉瘤的20%(10个中的2个)中检测到明显的流量不稳定性,而在44%(25个中的11个)中的悬垂的动脉瘤中。统计上,流动不稳定度量(通过在动脉瘤SAC上通过时间和空间平均的动能量化的动能量化)在破裂和未破裂的动脉瘤之间没有显着差异。相反,低壁剪切应力区域(LSA)和压力损失系数(PLC)与动脉瘤破裂的状态表现出显着的相关性。总之,本研究表明,流动不稳定性的存在可能与动脉瘤破裂的状态密切相关,至少对于ICA动脉瘤。另一方面,研究的回顾性和小样本大小可能在一定程度上损害了结论的可靠性,因此需要大规模的前瞻性研究进一步解决问题。 (c)2018年elestvier有限公司保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号