...
首页> 外文期刊>Journal of Biomechanics >A computational model of the hepatic circulation applied to analyze the sensitivity of hepatic venous pressure gradient (HVPG) in liver cirrhosis
【24h】

A computational model of the hepatic circulation applied to analyze the sensitivity of hepatic venous pressure gradient (HVPG) in liver cirrhosis

机译:应用肝循环的计算模型,用于分析肝硬化中肝静脉压梯度(HVPG)的敏感性

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Abstract Measurement of hepatic venous pressure gradient (HVPG) is currently widely adopted to provide an estimate of portal pressure gradient (PPG) in the diagnosis and treatment of portal hypertension associated with liver cirrhosis. Despite the well-documented clinical utility of HVPG, it remains poorly understood how the relationship between HVPG and PPG is affected by factors involved in the pathogenesis and progression of cirrhosis. In the study, a computational model of the hepatic circulation calibrated to in vivo data was developed to simulate the procedure of HVPG measurement and quantitatively investigate the error of HVPG relative to PPG under various pathophysiological conditions. Obtained results confirmed the clinical consensus that HVPG is applicable to the assessment of portal hypertension caused by increased vascular resistance located primarily at the sinusoidal and postsinusoidal sites rather than at the presinusoidal site. On the other hand, our study demonstrated that the accuracy of HVPG measurement was influenced by many factors related to hepatic hemodynamics even in the case of sinusoidal portal hypertension. For instance, varying presinusoidal portal vascular resistance significantly altered the difference between HVPG and PPG, while an enhancement in portosystemic collateral flow tended to improve the accuracy of HVPG measurement. Moreover, it was found that presinusoidal and postsinusoidal vascular resistances interfered with each other with respect to their influence on HVPG measurement. These findings suggest that one should take into account patient-specific pathological conditions in order to achieve a better understanding and utilization of HVPG in the clinical practice.
机译:摘要目前广泛采用肝静脉压梯度(HVPG)的测量,以提供与肝硬化相关的门静脉高血压的诊断和治疗中的门移压力梯度(PPG)的估计。尽管具有良好的HVPG临床效用,但它仍然明白HVPG和PPG之间的关系是如何受到涉及肝硬化发病机制和进展的因素的影响。在该研究中,开发了校准在体内数据中校准的肝循环的计算模型,以模拟HVPG测量的过程,并在各种病理生理病症下定量地研究HVPG相对于PPG的误差。获得的结果证实了HVPG适用于在主要位于正弦和初始位点的血管抗性增加而不是在教规性部位而导致的门孔高血压评估。另一方面,我们的研究表明,即使在正弦门户高血压的情况下,HVPG测量的准确性也受到与肝血流动力学相关的许多因素的影响。例如,不同的Presinuidal Portal血管阻力显着改变了HVPG和PPG之间的差异,而PortoSystemic侧面流量的增强趋于提高HVPG测量的准确性。此外,发现关于它们对HVPG测量的影响,预设曲线和初始血管电阻彼此干扰。这些研究结果表明,人们应该考虑到患者特异性病理条件,以便在临床实践中实现HVPG的更好理解和利用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号