Is the instrumented-pointer method of calibrating anatomical landmarks in 3D motion analysis reliable?

机译:是校准3D运动分析中的解剖标志的仪表指针方法可靠吗?

获取原文
获取原文并翻译 | 示例
           

摘要

Instrumented-pointers are often used to calibrate anatomical landmarks in biomechanical analyses. However, little is known about the effect of altering the orientation of the pointer during calibration on the co-ordinates recorded. Incorrect positioning of a landmark influences the axes created, and thus the kinematic data recorded. This study aimed to investigate the reliability of the pointer method for anatomical calibration. Two points were drawn onto a fixed box to resemble knee joint epicondyles, then a custom-made pointer was used to define the positions of these landmarks in three-dimensions. Twenty different pointer-orientations were chosen, and the position of the pointer in each of these orientations was recorded 8 times. Euclidean distances between single points were calculated for both landmarks and compared statistically (alpha = 0.05). Average Euclidean distances between all reconstructed points were 3.2 +/- 1.4 mm (range: 0.3-7.1 mm) for one landmark and 33 +/- 1.5 mm (range: 0.3-7.9mm) for the other. The x-and y-co-ordinates recorded differed statistically when the pointer was moved about the X and Y axes (anterior/posterior and superior/inferior to landmark) (p < 0.05). No statistical differences were found between co-ordinates recorded when the pointer was moved around the Z axes (p > 0.05). ICC values for all co-ordinates were excellent, highlighting the reliability of the method (ICC > 0.90). These results support this method of anatomical calibration; however, we recommend that pointers be consistently held in a neutral oriented position (where the handle is not anterior, posterior, superior or inferior to the landmark) during calibration, to reduce the likelihood of calibration errors. (C) 2017 Elsevier Ltd. All rights reserved.
机译:仪器指针通常用于校准生物力学分析中的解剖标志。然而,关于改变校准在记录的校准期间指针的方向的效果很少。标志性的定位不正确影响所创建的轴,从而记录的运动数据。本研究旨在研究解剖校准指针方法的可靠性。将两点拉到固定盒上以类似于膝关节髁,然后使用定制指针来定义三维地标的位置。选择了20个不同的指针取向,并且记录了每个方向中的指针的位置8次。为两个地标计算单点之间的欧几里德距离,并且统计上比较(alpha = 0.05)。所有重建点之间的平均欧几里德距离为3.2 +/- 1.4毫米(范围:0.3-7.1毫米),另一个地标,另外33 +/- 1.5 mm(范围:0.3-7.9mm)。当指针移动围绕X和Y轴移动时,记录的X-and Y-Co-ardInate在统计上差异(前/后和高级/较差的地标)(P <0.05)。在Z轴绕Z轴移动时记录的辅助记录之间没有发现统计差异(P> 0.05)。所有协调的ICC值都是优异的,突出了该方法的可靠性(ICC> 0.90)。这些结果支持这种解剖校准方法;然而,我们建议指针在校准期间始终保持在中性导向位置(手柄不是前部,后部,优于或较差),以降低校准误差的可能性。 (c)2017 Elsevier Ltd.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号