Cobalt complexes as internal standards for capillary zone electrophoresis-mass spectrometry studies in biological inorganic chemistry

机译:钴复合物作为生物无机化学中毛细管区电泳 - 质谱研究的内部标准

获取原文
获取原文并翻译 | 示例
           

摘要

Run-by-run variations are very common in capillary electrophoretic (CE) separations and cause imprecision in both the migration times and the peak areas. This makes peak and kinetic trend identification difficult and error prone. With the aim to identify suitable standards for CE separations which are compatible with the common detectors UV, ESI-MS, and ICP-MS, the CoIII complexes [Co(en)(3)]Cl-3, [Co(acac)(3)] and K[Co(EDTA)] were evaluated as internal standards in the reaction of the anticancer drug cisplatin and guanosine 5'-monophosphate as an example of a classical biological inorganic chemistry experiment. These CoIII chelate complexes were considered for their stability, accessibility, and the low detection limit for Co in ICP-MS. Furthermore, the CoIII complexes are positively and negatively charged as well as neutral, allowing the detection in different areas of the electrophero-grams. The background electrolytes were chosen to cover a wide pH range. The compatibility to the separation conditions was dependent on the ligands attached to the CoIII centers, with only the acetylacetonato (acac) complex being applicable in the pH range 2.8-9.0. Furthermore, because of being charge neutral, this compound could be used as an electroosmotic flow (EOF) marker. In general, employing Co complexes resulted in improved data sets, particularly with regard to the migration times and peak areas, which resulted, for example, in higher linear ranges for the quantification of cisplatin.
机译:逐行变化在毛细管电泳(CE)分离中非常常见,并且在迁移时间和峰面积中导致不精确。这使得峰值和动力学趋势识别困难和易于出错。旨在鉴定与常见探测器UV,ESI-MS和ICP-MS相容的CE分离的合适标准,COIII配合物[CO(EN)(3)] Cl-3,[CO(ACAC)( 3)]和K [CO(EDTA)]作为抗癌药物顺铂和鸟苷5'-单磷酸酯的反应中的内标评价为古典生物无机化学实验的一个例子。考虑这些COIII螯合物复合物的稳定性,可访问性和ICP-MS中CO的低检测限。此外,COIII络合物是正面和带负电的以及中性,允许检测电镀蛋白的不同区域。选择背景电解质以覆盖宽的pH范围。与分离条件的相容性取决于连接到COIII中心的配体,仅适用于pH范围2.8-9.0的乙酰丙酮(ACAC)复合物。此外,由于充电中性,该化合物可以用作电渗流(EOF)标记物。通常,采用CO复合物导致改进的数据集,特别是关于迁移时间和峰面积,其例如在更高的线性范围内用于定量顺铂。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号