A simple and sensitive method using high-performance liquid chromatography/ mass spectrometry (LC/MS) was developed and validated for simultaneous determination of 5 benzoylurea insecticides-diflubenzuron, triflumuron, teflubenzuron, lufenuron, and flufenoxuron-in tomatoes. Residues were successfully separated on a C18 column by methanol-water isocratic elution. Detection was carried out by an ultraviolet diode array detector (UV-DAD) coupled with a quadrupole mass spectrometer, using atmospheric pressure chemical ionization (APCI) in negative-ion mode. The main ions were the deprotonated molecules [M-H]- for triflumuron, and the anions formed by elimination of hydrofluoric acid [M-H-HF]- for diflubenzuron and flufenoxuron, and [M-2H-HF] for lufenuron and teflubenzuron. The calibration plots were linear for both detectors over the range 0.05 to 10 microg/mL, and the method presented good quality parameters. The limits of detection for standard solutions were 0.008-0.01 mg/L (equivalent to 0.08-0.1 ng injected) for both detectors, and the limits of quantification (LOQs) were approximately 10 times lower than national maximum residue levels (MRLs). Depending on the compound and the detector, the LOQ values ranged from 0.2 to 0.4 ng injected. The optimum LC-UV-DAD/APCI-MS conditions were applied to the analysis of benzoylureas in tomatoes. The obtained recoveries from fortified tomato samples (50 g), extracted with ethyl acetate and purified by solid-phase extraction on silica sorbent, were 88-100 and 92.9-105% for the UV-DAD and MS detectors, respectively, with precision values (relative standard deviations) of 2.9-11 and 3.7-14%, respectively. The method was applied to 12 tomato samples from local markets, and diflubenzuron and lufenuron were detected in only one sample at concentrations lower than the MRLs. The results indicate that the developed LC/MS method is accurate, precise, and sensitive for quantitative and qualitative analysis at low levels of benzoylureas required by legislation.
机译:使用高效液相色谱/质谱(LC / MS)的简单敏感的方法进行了开发和验证,同时测定5苯并脲杀虫剂 - Diflubenzuron,Triflumuron,Teflubenzuron,Lufenuron和Flufenoxuron - 在西红柿中。通过甲醇 - 水等物体洗脱成功在C18柱上成功分离残余物。检测通过耦合的紫外二极管阵列检测器(UV-DAD)与四极谱质谱仪,在负离子模式中使用大气压化学电离(APCI)。主要离子是去质子化分子[M-H] - 用于Triflumuron,以及通过消除氢氟酸[M-H-HF]而形成的阴离子 - 用于Lufenuron和Teflubenzuron的Diflubenzuron和Flufenoxuron,以及[M-2H-HF]。校准图对于两个探测器的线性为0.05至10 microg / ml,并且该方法呈现出质量良好的参数。检测器的标准溶液检测限率为0.008-0.01mg / L(相当于0.08-0.1ng注入的),并且量化的限制(LOQs)的限制约为国家最大残留水平(MRLS)。根据化合物和检测器,LOQ值范围为0.2至0.4ng注入。最佳的LC-UV-DAD / APCI-MS条件用于西红柿中苯甲酰脲的分析。用乙酸乙酯萃取并通过二氧化硅吸附剂的固相萃取纯化的加强化番茄样品(50g)的所得回收率分别为UV-DAD和MS探测器的88-100和92.9-105%,具有精确值(相对标准偏差)分别为2.9-11和3.7-14%。将该方法应用于来自局部市场的12种番茄样品,并且在低于MRL的浓度下仅在一个样品中检测到Diflubenzuron和Lufenuron。结果表明,发育的LC / MS方法是准确,精确,对立法所需的低水平苯甲酰脲的定量和定性分析进行准确,精确和敏感。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号