Caffeine is a common ingredient in beverages important to be monitored, as there are regulations worldwide. In this study, an analytical method was developed for routine caffeine determination in beverages. The sample pretreatment only takes a few minutes. Caffeine in the sample is extracted by 1 mL of ethyl acetate under sonication. The ethyl acetate phase is then dried by 0.08 g of anhydrous sodium sulfate and directly injected to gas chromatography-nitrogen phosphorus detector. The method was optimized to achieve high rate of recovery of 90.9-111.7% with RSD of <5% for fourteen real beverage samples. The method detection limit was 3.5 mg/L. Apart from the advantages of simplicity and rapidity, the method is relatively green, accurate, precise, sensitive, has a high throughput, low cost of operation and maintenance and can be recommended for the quantification of caffeine in various common beverages.
机译:咖啡因是饮料中的常见成分,重要的是监测,因为全世界都有规定。 在该研究中,开发了一种分析方法,用于饮料中的常规咖啡因测定。 样品预处理只需要几分钟。 样品中的咖啡因在超声处理下由1ml乙酸乙酯萃取。 然后将乙酸乙酯相用0.08g无水硫酸钠干燥,并直接注射到气相色谱 - 氮磷探测器。 该方法经过优化,以实现90.9-111.7%的高回收率,为14个真实饮料样品的RSD为<5%。 方法检测限为3.5mg /升。 除了简约和快捷的优点外,该方法还具有相对绿色,准确,精确,敏感,具有高通量,操作成本和维护成本,可以推荐在各种常见饮料中定量咖啡因。