...
首页> 外文期刊>Journal of aerosol medicine and pulmonary drug delivery >In Vitro Measurement of Regional Nasal Drug Delivery with Flonase,? Flonase? Sensimist,? and MAD Nasal? in Anatomically Correct Nasal Airway Replicas of Pediatric and Adult Human Subjects
【24h】

In Vitro Measurement of Regional Nasal Drug Delivery with Flonase,? Flonase? Sensimist,? and MAD Nasal? in Anatomically Correct Nasal Airway Replicas of Pediatric and Adult Human Subjects

机译:用Flonase ,?的体外测量区域鼻药递送 扑腾? 敏感,? 和疯狂的鼻腔? 在解剖学上纠正儿科和成人人类受试者的鼻气复制品

获取原文
获取原文并翻译 | 示例
           

摘要

Background: The majority of current nasal delivery devices, commercialized for children, are developed for adults. Differences in the dose reaching the target are expected due to significant differences between the pediatric and adult nasal airway geometries and their inhalation patterns. This study aims to compare the efficacy of most common nasal drug delivery devices in terms of regional delivery of suspension and solution formulations in pediatric and adult subjects.Methods: Anatomically correct nasal models of 2-, 5-, and 50-year old subjects were developed to evaluate regional nasal delivery of suspensions of fluticasone propionate and fluticasone furoate delivered with Flonase? and Flonase? Sensimist?, respectively, and the delivery of an aqueous solution of a model drug, administered with MAD Nasal?. Relevant inhalation patterns were considered for each nasal airway geometry. Controlled administration methods were used, and all contributing parameters, including particle size, velocity, and plume geometry, are reported.Results: Regional deposition patterns resulting from Flonase? Sensimist? and Flonase? were not significantly different in each replica (p?>?0.05), despite their different plume geometry and droplet size distributions. However, there was a significant difference in deposition of nasal sprays between the pediatric (2- and 5-year old) and adult models (p? ?0.05). The MAD atomizer resulted in different deposition patterns in all three subjects (p?
机译:背景:为成人开发了为儿童商业化的当前鼻输送设备的大部分。由于儿科和成人鼻道几何形状和吸入模式之间的显着差异,预期达到目标的剂量的差异。本研究旨在比较大多数常见的鼻药递送装置在儿科和成人对象中的悬浮液和溶液制剂的区域递送方面的疗效。方法:解剖学上的2-,5-和50岁的受试者的鼻型促进评估氟酮丙酸滴水悬浮液的区域鼻腔渗透,氟酮呋喃(氟螯合酶)用氟螯酶递送吗?和血液?敏感性敏感?,分别与模型药物水溶液的递送,用疯狂的鼻腔施用?每个鼻气气道几何都考虑了相关的吸入模式。使用受控给药方法,并报告所有贡献参数,包括粒度,速度和羽流几何形状。结果:氟蔗酶产生的区域沉积模式?敏感?和血液?尽管它们不同的羽流几何和液滴尺寸分布,但每次复制品(P?> 0.05)没有显着差异。然而,儿科(2-岁和5岁)和成人模型之间的鼻喷雾沉积存在显着差异(P?0.05)。疯狂的雾化器导致所有三个受试者的沉积图案不同(P?<?0.05)。结论:由于鼻部通道较窄和更大的前沉积(〜60%),鼻喷雾不是足够的儿科群体的递送装置。与鼻腔泵相比,MAD雾化器导致前沉积显着较低(〜10%-15%),但喉咙〜30%左右。包含解剖学校正鼻形几何形状和吸入模式的体外平台可以指导适当适当的鼻药输送装置的发展。

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号