PurposeCardiac resynchronization therapy (CRT) often requires a long fluoroscopic time and protection from scatter radiation. This study reports on scatter radiation levels during CRT, with and without additional shielding, and using standard or low pulse rate fluoroscopy.Materials and methodsAdditional lead-shielding drape (0.35-mm lead equivalent) was used on the left side of the table and pulsed fluoroscopy was performed at rates of 10 pulses/s (usual rate) and 7.5 pulses/s (low pulse rate). Fluoroscopy scatter radiation was measured for both pulse rates using an acrylic phantom with a radiation survey meter, both with and without the additional lead-shielding drape.ResultsWith the additional lead-shielding drape, the fluoroscopy scatter radiation was reduced by 74.3% at 10 pulses/s and 78.6% at 7.5 pulses/s. If the fluoroscopy was changed from 10 pulses/s to 7.5 pulses/s, the scattered radiation at the primary physician's position was reduced by 24.0%. The combined use of additional shielding drape and low pulse rate fluoroscopy reduced scatter radiation by over 80%.ConclusionAdditional lead-shielding drape and low pulse rate fluoroscopy are effective in reducing the scattered radiation dose to physicians and nurses during CRT.
机译:PurposearAdiac Acconization治疗(CRT)通常需要长透视时间和保护免受散射辐射。本研究报告了CRT期间的散射辐射水平,随着额外的屏蔽,并且使用标准或低脉冲速率荧光检查。在桌子的左侧使用了一系列材料和方法加法帘线(0.35mm铅铅等同)以10个脉冲/ s(通常速率)和7.5脉冲/ s(低脉冲率)的速率进行荧光镜检查。使用丙烯酸模型测量荧光镜散射辐射,使用丙烯酸体模,含有辐射测量仪,无论是额外的引线屏蔽窗口,否则透视散射辐射都会在10个脉冲处减少74.3% / s在7.5脉冲/ s时78.6%。如果荧光透视从10个脉冲或7.5脉冲/ s变为7.5脉冲/ s,则主要医师位置的散射辐射减少了24.0%。结合使用额外的屏蔽悬垂和低脉冲率荧光透视减少了80%以上的散射辐射。Conlusionadditional铅屏蔽悬垂性和低脉搏率荧光检查有效地将散射的辐射剂量降低到CRT期间的医生和护士。

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号