Evaluation of the Luminex ARIES (R) system for the detection and quantification of BK virus (BKV) DNA in plasma samples from kidney transplant recipients

机译:肾移植受者血浆样品中BK病毒(BKV)DNA检测和定量BK病毒(BKV)DNA的评价

获取原文
获取原文并翻译 | 示例

摘要

BK virus (BKV) nephropathy is a serious complication in renal transplant recipients due to the need for immuno-suppression. Nearly 50% of renal transplant patients with BKV nephropathy experience a significant loss of function of the transplanted kidney. It is routine practice to screen renal transplant recipients regularly for BK viremia. In this study, we compared the performance of BIN quantitative polymerase chain reaction analyte specific reagents by ELITech and Luminex for measuring BIN viral load in plasma using the Roche Cobas (R) z480 instrument and the Luminex ARIES (R) platform, respectively. A total of 34 patients previously tested on the z480, with results spanning the test's linear range, were analyzed on the ARIES (R). The BKV DNA copy number correlation between the 2 methods was very good, with an R-2 value of 0.96. The average difference in log copy number between the 2 methods was -0.3, indicating that the ARIES (R) method may have slightly greater analytical sensitivity. BKV quantification results were closely matched between the 2 different methods. The workflow with the ARIES (R) System is greatly simplified by elimination of DNA extraction and most hands-on steps. The high degree of automation allows samples to be tested as they arrive into the laboratory, resulting in enhanced patient care due to more rapid turnaround time for results back to the ordering physician. (C) 2018 Elsevier Inc. All rights reserved.
机译:BK病毒(BKV)肾病是肾移植受害者的严重并发症,因为需要免疫抑制。近50%的肾移植患者BKV肾病患者经历移植肾功能的显着损失。常规做法定期筛查肾移植受体,用于BK病毒血症。在这项研究中,我们将Elitech和Luminex的eLitech和Luminex的性能进行了比较使用Elitech和Luminex来测量血浆中的肠道病毒载体,分别使用RocheCobasZ480仪器和Luminex白羊座(R)平台来测量血浆中的肠病毒载荷。在ARIES(R)上分析了总共在Z480上测试的34例患者以前在Z480上进行了测试的结果。 2种方法之间的BKV DNA拷贝数相关性非常好,R-2值为0.96。 2方法之间的日志拷贝数的平均差异为-0.3,表明白羊座(R)方法可能具有稍大的分析灵敏度。 BKV定量结果与2种不同的方法密切相关。通过消除DNA提取和大多数实践步骤,大大简化了与白羊座(R)系统的工作流程。高度的自动化允许在到达实验室时进行测试,导致患者护理增强,由于结果返回到订购医师的更快的周转时间。 (c)2018年Elsevier Inc.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号