VOLTAGE PULSES from a variable speed drive can couple from a motor's stator to its rotor, causing a voltage to appear on the rotor shaft. When this rotor shaft voltage exceeds the insulating capacity of the bearing grease, voltage arcs or electrical discharge machining can occur, causing pitting and fluting of the motor bearing race, damage that can cause a motor to fail prematurely. This application note explains how to use the MDA-550 Motor Drive Analyser and a shaft voltage probe to measure motor shaft voltage discharge events.
机译:来自变速驱动器的电压脉冲可以从电动机的定子耦合到其转子,导致转子轴上出现电压。 当该转子轴电压超过轴承润滑脂的绝缘容量时,可能会发生电压或电气放电加工,导致电机轴承座圈的蚀和烧毁,可能导致电机过早失效的损坏。 本应用笔记说明如何使用MDA-550电机驱动分析仪和轴电压探头来测量电机轴电压放电事件。