首页> 外文期刊>Hip international: the journal of clinical and experimental research on hip pathology and therapy >Clinical and radiological results with a 36-mm cobalt-chrome prosthetic head, cross-linked Durasul liners associated with Allofit cups: a more than 10-year follow-up period
【24h】

Clinical and radiological results with a 36-mm cobalt-chrome prosthetic head, cross-linked Durasul liners associated with Allofit cups: a more than 10-year follow-up period

机译:临床和放射性结果与36毫米钴 - 铬的假肢头,交联的Durasul衬里与Allofit Cups相关联:超过10年的随访期

获取原文
获取原文并翻译 | 示例
           

摘要

Background: Highly cross-linked polyethylene is currently a common articulation surface used for total hip arthroplasty (THA). Aim: The aim of the present study is in vivo assessment of highly cross-linked Durasul polyethylene linear and volumetric wear when associated with a 36-mm prosthetic femoral head. Methods: We retrospectively reviewed clinical and radiographic data of 78 patients (81 hips) having primary THAs using Durasul liner combined with a 36-mm CoCr prosthetic head. All of them were followed for more than 10 years. Patient outcome was assessed with the Harris Hip Score (HHS) preoperatively and at last follow-up. 2-D prosthetic head penetration into polyethylene, 3D wear rates and cup migration were evaluated. Results: The preoperative and last follow-up HHS were 50.43 +/- 10.42 and 97.44 +/- 5.51 respectively. The annual penetration of the prosthetic head into Durasul (R) liner was 0.029 +/- 0.003 mm. The annual linear penetration and volumetric wear extrapolation rates using Charnley and Ilchmann formulas were 37.84% and 57.76% respectively of that seen with conventional polyethylene liner. At last follow-up, the total loss of material in Durasul represents only 0.15% of the initial polyethylene mass. We did not observe any significant cup migration in the study group. Conclusions: Results are promising, and we believe that these data authorise the continued use of highly cross-linked polyethylene liner associated with a 36-mm prosthetic head for total hip arthroplasties in older patients. More long-term follow-up studies are mandatory before we feel comfortable with the project of using cross-linked polyethylene in young and active patients instead of ceramic-on-ceramic bearings.
机译:背景:高度交联聚乙烯是目前用于总髋关节置换术(THA)的常见关节表面。目的:本研究的目的是在与36毫米假体股头相关时对高度交联的DURASUL聚乙烯线性和体积磨损的体内评估。方法:通过使用Durasul衬垫结合36毫米COLD假肢,回顾性地审查了78名患者(81髋)的临床和放射线图,其中包含了初级THA。所有这些都被遵循超过10年。患有患者的结果术前和最后一次随访评估哈里斯臀评分(HHS)。评估二乙醚的2-D假期渗透,3D磨损率和杯迁移。结果:术前和最后一次随访HHS分别为50.43 +/- 10.42和97.44 +/- 5.51。假肢进入durasul(r)衬里的年度渗透为0.029 +/- 0.003 mm。使用Charnley和Ilchmann公式的每年线性穿透和体积磨损外推率分别与常规聚乙烯衬里分别为37.84%和57.76%。在最后的随访中,Durasul中材料的总损失仅占初始聚乙烯质量的0.15%。我们没有观察到研究组中的任何重要杯迁移。结论:结果很有希望,我们认为这些数据授权继续使用与36毫米假肢头相关的高度交联的聚乙烯衬垫,用于老年患者的总髋关节关节塑料。在我们对年轻和活性患者中使用交联聚乙烯的项目感到舒适之前,必须长期后续研究是强制性的。

著录项

相似文献

  • 外文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号