Purpose: This study evaluated the effect of the level of the prosthetic construction on the marginal bone stability around extra-short implants (= 6.5 mm in length) supporting a fixed prosthesis. Materials and Methods: This retrospective study was performed at a private dental clinic. The patient charts were reviewed to select those who had an extra-short implant (= 6.5 mm in length) supporting a fixed prosthesis. A transmucosal abutment (transepithelial Multi-fm, BTI Biotechnology Institute) was used in those implants that were restored at the gingival level. Otherwise, the implants were restored at the platform level. Demographic data and implant-related and prosthesis-related variables were obtained. Results: Thirty-three extra-short implants in 17 patients were assessed. The patients' mean age was 61 +/- 12 years at the time of surgery. The prosthetic reconstruction was done at the platform level in 18 implants and at the gingival level (via transmucosal abutment) in 15 implants. Considering the use or not of a transmucosal abutment, there were no statistically significant differences in all studied variables except bone stability. The extra-short implants that were restored at the platform level experienced more crestal bone loss (P = .024). Conclusion: The extra-short implant restoration at the gingival level would increase the stability of the marginal bone.
机译:目的:本研究评估了假体结构水平对超短植入物(长度长度)的边际骨稳定性的影响,支持固定假体。材料和方法:此回顾性研究是在私人牙科诊所进行的。审查患者图表以选择具有超短植入物的人(& = 6.5 mm的长度),支持固定的假体。在牙龈水平恢复的那些植入物中使用渗漏型邻接(Transepithelial Multi-FM,BTI生物技术学院)。否则,植入物在平台级别恢复。获得人口统计数据和相关的和植入和假体相关的变量。结果:17例患者的三十三种超短植入物进行了评估。在手术时,患者的平均年龄是61 +/- 12岁。假体重建在18种植入物中的平台水平和15个植入物中的牙龈水平(通过弥囊邻接)进行。考虑到使用或不透气胶粘剂邻接,除了骨稳定性之外的所有研究变量没有统计学显着的差异。在平台层面恢复的超短植入物经历了更多的骨折骨质损失(P = .024)。结论:牙龈水平的超短植入物恢复将增加边际骨的稳定性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号