首页> 外文期刊>Transactions of the ASABE >ASSESSMENT OF FLUORESCENT DYE BRILLIANT SULFAFLAVINE DEPOSITION ON STAINLESS STEEL SCREENS AS SPRAY DROPLET COLLECTORS
【24h】

ASSESSMENT OF FLUORESCENT DYE BRILLIANT SULFAFLAVINE DEPOSITION ON STAINLESS STEEL SCREENS AS SPRAY DROPLET COLLECTORS

机译:不锈钢屏幕上荧光染料辉煌苏氟芬沉积的评估为喷雾液滴收集器

获取原文
获取原文并翻译 | 示例
           

摘要

The fluorescent dye Brilliant Sulfaflavine (BSF, CAS 2391-30-2) was investigated to determine its photo-stability and recovery on five spray deposition collectors: white plastic plate, nylon screen, and stainless steel (SS) screens of three mesh sizes (40, 60, and 80). The photo-stability of the deposited dye was determined by measuring the variance in fluorescence intensity after daylight exposure. The recovery rates were investigated with statically dispensed droplets and dynamically discharged droplets. In addition, droplet penetration through the screen collectors and the amount of unrecovered dye on reprocessed collectors were assessed to better understand the differences in dye recovery rates among different collector types. Photo-degradation tests verified that all collector types were insignificant in fluorescence degradation ( 3.1%) after 120 min of solar exposure. Nylon screens had the lowest dye recovery rate (87.0%) for statically dispensed droplets, whereas plastic plates and SS screens recovered more than 90% of deposited dye. For dynamically discharged droplets, the 60-mesh and 80-mesh SS screens recovered more than 70% of the deposited dye, whereas nylon screens showed less than 50% recovery rate. These results were substantiated visually with a high-speed imaging system that detected droplets penetrating more frequently through screens with larger mesh openings. Throughout ten continuous reprocessing cycles of the fluorimetry test, the fluorescence intensity on reprocessed nylon and 80-mesh SS screen collectors increased by 16.8% and 12.7%, respectively, while there was less than 1% change in fluorescence intensity on the 40-mesh and 60-mesh SS screens. These results were clarified through dye residue verification using digital image analysis.
机译:研究了荧光染料辉煌苏福拉夫林(BSF,CAS 2391-30-2)以确定其光稳定性和五个喷雾沉积收集器的恢复:白色塑料板,尼龙屏幕和三种网眼尺寸的不锈钢(SS)屏幕( 40,60和80)。通过测量白天暴露后的荧光强度的差异来测定沉积染料的光稳定性。通过静态分配的液滴和动态排出的液滴来研究回收率。此外,通过筛选器的液滴渗透和再加工收集器上的未恢复染料的量进行评估,以更好地了解不同收集器类型之间的染料回收率的差异。光降解试验证明,在120分钟的太阳能暴露后,所有收集器类型在荧光降解(& 3.1%)中都是微不足道的。尼龙屏幕具有最低的染料回收率(87.0%),用于静态分配的液滴,而塑料板和SS屏幕恢复超过90%的沉积染料。对于动态排出的液滴,60目和80目SS屏幕恢复超过70%的沉积染料,而尼龙屏幕显示出小于50%的回收率。这些结果以高速成像系统在视觉上证实,该系统通过具有较大网状开口的屏幕更频繁地检测到液滴更频繁地穿透。在整个荧光测定试验的十个连续再加工循环中,再加工尼龙和80目SS筛网收集器上的荧光强度分别增加了16.8%和12.7%,而40目和40型荧光强度的变化少于1%。 60-网格SS屏幕。通过使用数字图像分析,通过染料残留验证澄清这些结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号