A graphene paper-based flexible solid-contact ion-selective electrode (SC-ISE) was developed to detect lead ion sensitively. Graphene paper obtained via a simple vacuum filtration method was used as the electrode substrate for direct coating of an ion-selective membrane. The Nernstian slope of the prepared paper-based potentiometric sensor toward lead ion detection was demonstrated as 29.4 mV per decade. A detection limit as low as 2.5 x 10(-7) mol L-1 was achieved. Reversed chronopotentiometry and water layer test revealed that the graphene paper-based SC-ISE possessed excellent potential stability because of the hydrophobicity of graphene paper. Furthermore, reliable data were obtained from the detection of lead ion levels in real water samples using the graphene paper-based potentiometric sensor, which shows great potential in practical application.
机译:开发了基于石墨烯纸的柔性固体接触离子选择电极(SC-ISE)以敏感地检测铅离子。 通过简单的真空过滤方法获得的石墨烯纸作为电极基板,用于直接涂覆离子选择性膜。 制备的纸型电位传感器的内部坡度朝向铅离子检测被证明为每十年29.4 mV。 达到低至2.5×10(-7)摩尔L-1的检出限。 逆转时间表测定和水层试验显示,由于石墨烯纸的疏水性,石墨烯纸的SC-ise具有优异的潜在稳定性。 此外,使用石墨烯纸电位传感器从实际水样中检测到实际水样中的铅离子水平的可靠数据,这在实际应用中具有很大的潜力。