首页> 外文期刊>Therapeutic hypothermia and temperature management >Effect of 'An Innovative Technology' Active Warming and Passive Warming on Unplanned Hypothermia During Perioperative Period: A Clinical Trial
【24h】

Effect of 'An Innovative Technology' Active Warming and Passive Warming on Unplanned Hypothermia During Perioperative Period: A Clinical Trial

机译:“创新技术”主动变暖和被动变暖对外星性近期无计划体温过低的影响:临床试验

获取原文
获取原文并翻译 | 示例

摘要

Patients are at risk for unplanned hypothermia during the perioperative period due to many reasons, including anesthesia, low room temperature, cold intravenous fluid, and blood transfusion. This study was conducted to examine the effect of active and passive warming methods applied in patients during the perioperative period on unplanned hypothermia. This study is a case-control type study. The population of this study is composed of the patients hospitalized in surgical clinic and undergone abdominal region-related operations. Ninety patients were accidentally included in the study. The first group of patients were actively warmed during the perioperative period (carbon fiber resistive system - W-500D + 190 x 50 cm), the second group was passively warmed at least for 20 minutes during preoperative period (with blanket, socks etc.), and the third group was followed up as the control group. It was established that body temperature average of the active warming group has significantly increased during perioperative period (p < 0.001), and this temperature was significantly higher than the other groups until the third hour. It was found that the body temperature average of all groups was equal to 36.2 ±0.26, 35.4 ±0.49, and 35.2 ±0.47, respectively, at the end of operation, and the difference among them was statistically significant (p ≤ 0.001). The active warming method applied with carbon fiber resistive system during the perioperative period is an effective method.
机译:由于许多原因,包括麻醉,低室温,冷静脉内液和输血,患者在外术期间存在无计划的体温过低的风险。进行该研究以检测在无计划低温围手术期间患者中施用的活性和被动变暖方法的效果。本研究是一个案例对照类型的研究。本研究人口由在外科诊所和经历腹部区域相关操作中住院的患者组成。九十名患者被意外纳入该研究。在围手术期(碳纤维电阻系统 - W-500d + 190×50厘米)期间,第一组患者在围手术期(碳纤维电阻系统 - W-500D + 190×50厘米)中,在术前期间至少持续20分钟(带毯子,袜子等) ,第三组随访是对照组。建立了在围手术期期间活性升温组的体温平均值显着增加(P <0.001),该温度明显高于其他组,直至第三小时。结果发现,所有基团的体温平均值分别在操作结束时分别等于36.2±0.26,35.4±0.49和35.2±0.47,35.2±0.47。它们的差异有统计学意义(P≤0.001)。在围手术期间施用碳纤维电阻系统的主动变暖方法是一种有效的方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号