首页> 外文期刊>The Journal of the American Academy of Orthopaedic Surgeons >Addressing Antibiotic Hip Spacer Instability via Hybrid Screw-cement Fixation of a Constrained Liner and Cement-rebar Interface Techniques: A Technical Narrative
【24h】

Addressing Antibiotic Hip Spacer Instability via Hybrid Screw-cement Fixation of a Constrained Liner and Cement-rebar Interface Techniques: A Technical Narrative

机译:通过约束衬里和水泥钢筋界面技术的混合螺旋水泥固定来解决抗生素髋关节间隔物不稳定性:技术叙事

获取原文
获取原文并翻译 | 示例
       

摘要

Prosthetic joint infection is a challenging and devastating complication after total hip arthroplasty. The benchmark for treatment remains two-stage revision arthroplasty, in which an antibiotic-impregnated spacer is used to eradicate the infection. Although several types of spacer constructs have been described, they have historically been associated with high rates of mechanical complications, namely, dislocation, spacer fracture, and periprosthetic femur fracture. Spacer dislocation is the most common, with reported rates as high as 41%. Here, the authors present a surgical technique to improve the mechanical stability of an articulating hip spacer via a hybrid screw-cement fixation technique that allows for joint motion and weight bearing during the treatment period while minimizing the risk of mechanical failure. An additional technique is described to address acetabular bone loss, which has been associated with a higher spacer dislocation rate, through a cement-rebar interface construct.
机译:假肢关节感染是全髋关节置换术后的挑战性和毁灭性的并发症。治疗的基准仍然是两阶段修正关节成形术,其中使用抗生素浸渍的间隔物来消除感染。虽然已经描述了几种类型的间隔结构,但它们历史上与高机械并发症率相关,即脱位,间隔骨折和股骨骨折骨折。间隔脱位是最常见的,报告的率高达41%。这里,作者呈现了一种手术技术,通过混合螺旋水泥固定技术来改善铰接髋桩间隔物的机械稳定性,其允许在治疗期间接合运动和重量轴承,同时最小化机械故障的风险。描述了一种通过水泥 - 钢筋接口构造来解决与较高的间隔位错率相关联的髋臼骨损失。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号