The accuracy of the “projected surgical transepicondylar axis” relative to the “true surgical transepicondylar axis” in total knee arthroplasty

机译:“投影外科手术特敏轴轴”相对于“真正的外科龙眼膜轴”的总膝关节形成术

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

Abstract Background In TKA, we have used the “projected SEA”, which is obtained by projecting the “true SEA” on the distal femoral cutting plane in clinical practice to determine the femoral component rotation. There are no reports examining the accuracy of the “projected SEA”. In this study, we investigated the difference between the “true SEA” and “projected SEA”. Methods The present study was a CT-based computer-simulated case series. We evaluated 34 knees without osteoarthritis changes. These patients were selected from the operative schedule prior to THA. We defined the “true SEA” on the 3D model and the “projected SEA” on the cutting plane parallel to the distal femoral axis obtained based on the “true SEA”. We changed the cutting angles from 20° flexion to 20° extension, and from five degrees varus to five degrees valgus. We measured the “true SEA angle” and “projected SEA angle” regarding the posterior condylar axis (PCA). Results The mean “true SEA angle” was 3.04°±1.34° (0.6–5.0°). The mean “projected SEA angle” was 3.43°±1.58° at 20° flexion, 3.42°±1.56° at 0° flexion, 3.43°±1.52° at 20° extension, 3.39°±1.59° at five degrees valgus, and 3.39°±1.50° at five degrees varus. At each cutting angle, the “projected SEA angle” was significantly larger than the “true SEA angle” (p 0.001). Conclusions We found that the true SEA and projected SEA do not differ significantly (0.39°±0.29° [range 0–1.0°]).
机译:抽象背景在TKA,我们使用了“投影海”,通过在临床实践中投射了“真正的海线”,以确定股骨成分旋转。没有报告检查“投影海洋”的准确性。在这项研究中,我们调查了“真正的海”和“投影海”之间的差异。方法本研究是基于CT的计算机模拟案例系列。我们评估了34个没有骨关节炎的膝关节。这些患者选自在该患者之前选择的。我们在3D模型上定义了“真正的海”,并平行于基于“真海”获得的远端股骨轴的切割平面上的“投影海”。我们将切削角度从20°屈曲到20°延伸,从五个差异到五度Valgus。我们测量了关于后髁轴(PCA)的“真正的海角”和“投射海角度”。结果平均“真正的海角”为3.04°±1.34°(0.6-5.0°)。平均“投射海角度”为20°屈曲,3.42°±1.56°,3.43°±1.52°,3.43°±1.52°,3.39°±1.59°,3.39 °±1.50°在5度差异。在每个切割角度下,“投射海角度”显着大于“真正的海角”(p 0.001)。结论我们发现真正的海洋和投影大海没有显着差异(0.39°±0.29°[范围0-1.0°])。

著录项

  • 来源
    《The Knee》 |2017年第6期|共7页
  • 作者单位

    Department of Orthopedic Surgery Graduate School of Medical Science Kanazawa University;

    Department of Orthopedic Surgery Graduate School of Medical Science Kanazawa University;

    Department of Orthopedic Surgery Graduate School of Medical Science Kanazawa University;

    Department of Orthopedic Surgery Graduate School of Medical Science Kanazawa University;

    Department of Orthopedic Surgery Graduate School of Medical Science Kanazawa University;

    Department of Orthopedic Surgery Graduate School of Medical Science Kanazawa University;

    Department of Orthopedic Surgery Graduate School of Medical Science Kanazawa University;

    Department of Orthopedic Surgery Graduate School of Medical Science Kanazawa University;

    Department of Orthopedic Surgery Graduate School of Medical Science Kanazawa University;

    Department of Orthopedic Surgery Graduate School of Medical Science Kanazawa University;

    Department of Orthopedic Surgery Fukui General Hospital;

    Department of Orthopedic Surgery Graduate School of Medical Science Kanazawa University;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 骨科学(运动系疾病、矫形外科学);
  • 关键词

    TKA; True SEA; Projected SEA;

    机译:TKA;真正的海;投影大海;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号