...
首页> 外文期刊>The Journal of oral implantology >Effect of Implant Position and Edentulous Span Length on Stresses Around Implants Assisting Claspless Distal Extension Partial Overdentures: An In Vitro Study
【24h】

Effect of Implant Position and Edentulous Span Length on Stresses Around Implants Assisting Claspless Distal Extension Partial Overdentures: An In Vitro Study

机译:植入物位置和透明跨度长度对植入物临时伸缩局部延伸部分覆盖的应力的影响:体外研究

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

The aim of this in vitro study was to evaluate the effect of implant position and edentulous span length on stresses around implants assisting claspless distal extension partial overdentures. Four bilateral mandibular distal extension acrylic models were constructed. Two implants were inserted in the distal extension ridges parallel to each other and perpendicular to the ridges. Based on the implant position, models were categorized into two groups: Group I, mesial implants position and Group II, distal implant position. Each group was subdivided into 2 subgroups according to the length of edentulous span: Subgroup a, long span and Subgroup b, short span. Four claspless partial overdentures were fabricated on the models and retained to the implants with ball-and-socket attachments. Three strain gauges were cemented to the acrylic resin at buccal, lingual, and distal sides of each implant. Static unilateral vertical load of 60N was applied in the central fossae of the first molar, and pen-implant stresses were measured on loading and nonloading sides. Distal implant placements recorded significantly higher peri-implant stresses than did mesial implant placements. Long saddle recorded significantly higher stresses than did short saddle. The greatest peri-implant stresses were recorded with distal placement and long saddle at the loading side. At loading and nonloading sides, the mesial placement with a short saddle recorded the lowest strain. For mandibular distal extension partial overdentures, a mesially placed implant combined with short saddle may be preferable to a distally placed implant combined with long saddle, as the former was associated with reduced pen-implant stresses.
机译:这种体外研究的目的是评估植入物位置和透明跨度长度对辅助栓塞远端延伸部分覆盖的应力的影响。构建了四种双侧下颌远端延伸丙烯酸模型。将两个植入物插入彼此平行并垂直于脊的远侧延伸脊。基于植入物位置,模型分为两组:I族,间谍植入物位置和第II族,远端植入物位置。根据凭证跨度的长度细分为2个子组:子组A,长跨度和子组B,短跨度。在模型上制造了四个扣紧部分覆盖,并保留在带有球形套管附件的植入物中。在每个植入物的颊,舌和远侧侧面粘合到丙烯酸树脂中的三个应变计。静态单侧垂直载荷的60n施加在第一磨牙的中央骨骼中,并在装载和偏压上测量笔植入胁迫。远端植入物放置记录显着更高的围植入压力,而不是薄层植入物介绍。长马鞍记录的应力明显高于短鞍座。在装载侧的远端放置和长鞍座中记录了最大的静胞植入应力。在装载和非加载侧面,具有短鞍座的界面放置记录了最低应变。对于下颌远端延伸部分覆盖,与短鞍座合并的型膀胱置入的植入物可以优选地与长鞍板组合的远端放置的植入物,因为前者与减少的笔植入物应力相关。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号