...
首页> 外文期刊>Proceedings of the Institution of Mechanical Engineers, Part H. Journal of Engineering in Medicine >The dependence of broadband ultrasound attenuation on phase interference in thin plates of variable thickness and curvature: a comparison of experimental measurement and computer simulation
【24h】

The dependence of broadband ultrasound attenuation on phase interference in thin plates of variable thickness and curvature: a comparison of experimental measurement and computer simulation

机译:宽带超声衰减对可变厚度薄板薄板相干扰的依赖性:实验测量与计算机仿真的比较

获取原文
获取原文并翻译 | 示例

摘要

The measurement of broadband ultrasound attenuation describes the linear increase in ultrasound attenuation with frequency (dB/MHz); this is generally performed at the calcaneus, consisting of a high proportion of metabolically active cancellous bone. Although broadband ultrasound attenuation is not routinely implemented within clinical management since it cannot provide a reliable estimation of bone mineral density and hence clinical definition of osteopenia and osteoporosis, it offers a reliable means to predict osteoporotic fracture risk. One of the potential factors that can influence the accuracy of broadband ultrasound attenuation measurement is the effect of cortical end plates. This study aimed to explore this, performing a comparison of experimental study and computer simulation prediction. A total of three categories of thin discs were three-dimensional (3D) printed to replicate cortical shells of (1) variable constant thickness (planar), (2) variable constant thickness (curved), and (3) variable thickness. A through-transmission technique was used, where two single-element, unfocused, 1 MHz broadband transducers, as utilised clinically, were positioned coaxially in a cylindrical holder and immersed in water. Both quantitative and qualitative analyses demonstrated that broadband ultrasound attenuation measurements of the planar' and curved' discs were not statistically different (p-values 0.01). A cyclic relationship between broadband ultrasound attenuation and disc thickness was observed; this was replicated within a computer simulation of phase interference created by a double-reflection echo within each disc (R-2 = 97.0%). Variable-thickness discs provided broadband ultrasound attenuation measurements ranging between 31.6 +/- 0.1 and 40.60 +/- 0.1 dB/MHz. Again applying the double-reflection echo simulation, a high level of agreement between experimental and simulation was recorded (R-2 = 93.4%). This study indicates that the cortical end plate can
机译:宽带超声衰减的测量描述了用频率(DB / MHz)超声衰减的线性增加;这通常在钙烷中进行,由高比例的代谢活性松散骨组成。尽管在临床管理中没有常规实施宽带超声衰减,因为它无法提供对骨矿物密度的可靠估计,因此骨质缺陷和骨质疏松症的临床定义,它提供了可靠的方法来预测骨质疏松骨折风险。可以影响宽带超声衰减测量精度的潜在因素之一是皮质端板的影响。本研究旨在探索这一点,执行实验研究和计算机模拟预测的比较。共有三类薄圆盘是三维(3D)印刷以复制皮质壳(1)可变恒定厚度(平面),(2)可变恒定厚度(弯曲),(3)可变厚度。使用贯通传输技术,其中临床上使用两个单元素,未聚焦,1 MHz宽带换能器同轴地定位在圆柱形支架中并浸入水中。定量和定性分析都证明了平面'和弯曲'光盘的宽带超声衰减测量没有统计学不同(p值& 0.01)。观察到宽带超声衰减与盘厚度之间的循环关系;这在通过每个盘内的双反射回声产生的相位干扰的计算机模拟中复制了这一点(R-2 = 97.0%)。可变厚度盘提供宽带超声衰减测量范围,范围在31.6 +/- 0.1和40.60 +/- 0.1 dB / MHz之间。再次施加双反射回声仿真,记录了实验和模拟之间的高度协议(R-2 = 93.4%)。本研究表明皮质端板可以

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号