The acoustic emission (AE) method has been widely recognized for the detection of incipient insulation fault phenomenon (partial discharge, PD) in power transformers, nevertheless, the installation and placement of AE sensors should be taken into full consideration. In this manuscript, a three-dimensional multiphysics model was established and simulated to research the characteristics of the propagation in the transformer wall. Furthermore, a piezoelectric transducer was used to detect PD ultrasonic signals and verify the simulation results in the laboratory. To ensure the accuracy of the detection, an optical fiber sensor based on the Sagnac interference principle was designed and adopted. The variation of the amplitude of the ultrasonic signal with distance reveals the characteristics of the ultrasonic signal propagating in the transformer wall. The distribution of sound pressure on the upper and lower surfaces of the simulation model proved that ultrasonic waves propagate in the form of symmetrical Lamb waves in the transformer wall. Moreover, the amplitude of the AE attenuates due to absorption and refraction loss, and local fluctuations on account of acoustic interference. Thus, a stable signal detected by an AE sensor does not represent the absence of PD in a transformer. To improve the reliability of AE detection, it is proposed in this manuscript that repeated movement of the AE sensor is necessary to obtain a suitable measurement position. Similarly, it is necessary to adjust the position of the AE sensor in order to locate the PD source well. In addition, this study is expected to provide a theoretical analysis and a fiber sensor to address the problem of sensor placement in AE detection.
机译:已经广泛认识到声学发射(AE)方法用于检测电力变压器中的初期绝缘故障现象(局部放电,PD),但AE传感器的安装和放置应充分考虑。在该稿件中,建立了一个三维多体模型,并模拟以研究变压器壁中传播的特性。此外,使用压电换能器来检测PD超声信号并验证实验室的模拟结果。为确保检测的准确性,设计并采用了基于SAGNAC干扰原理的光纤传感器。具有距离的超声波信号的幅度的变化揭示了在变压器壁中传播的超声信号的特性。仿真模型的上表面和下表面上的声压分布证明,超声波以变压器壁中的对称羊波的形式传播。此外,由于吸收和折射损失,AE衰减的幅度,并且由于声干扰而导致的局部波动。因此,由AE传感器检测的稳定信号不代表在变压器中不代表PD。为了提高AE检测的可靠性,提出在该稿件中,即所需的AE传感器的重复运动以获得合适的测量位置。类似地,有必要调整AE传感器的位置以便定位PD源阱。此外,该研究预计提供理论分析和光纤传感器,以解决AE检测中的传感器放置问题。

著录项

  • 来源
    《Plasma Science & Technology》 |2020年第2期|共9页
  • 作者单位

    Nanjing Univ Aeronaut &

    Astronaut Jiangsu Key Lab New Energy Generat &

    Power Conver Nanjing 211106 Peoples R China;

    Nanjing Univ Aeronaut &

    Astronaut Jiangsu Key Lab New Energy Generat &

    Power Conver Nanjing 211106 Peoples R China;

    Nanjing Univ Aeronaut &

    Astronaut Jiangsu Key Lab New Energy Generat &

    Power Conver Nanjing 211106 Peoples R China;

    North China Elect Power Univ State Key Lab Alternate Elect Power Syst Renewabl Beijing 102206 Peoples R China;

    Nanjing Univ Aeronaut &

    Astronaut Jiangsu Key Lab New Energy Generat &

    Power Conver Nanjing 211106 Peoples R China;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 物理学;
  • 关键词

    partial discharge; power transformer; ultrasonic detection; optical fiber; Sagnac interference;

    机译:局部放电;电力变压器;超声波检测;光纤;SAGNAC干扰;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号