首页> 外文期刊>Corrosion Engineering, Science and Technology >Influence of alternating voltages on passivation and corrosion properties of X80 pipeline steel in high pH 0.5 mol L-1 NaHCO3+0.25 mol L-1 Na2CO3 solution
【24h】

Influence of alternating voltages on passivation and corrosion properties of X80 pipeline steel in high pH 0.5 mol L-1 NaHCO3+0.25 mol L-1 Na2CO3 solution

机译:交流电压对X80管线钢在高pH 0.5 mol L-1 NaHCO3 + 0.25 mol L-1 Na2CO3溶液中钝化和腐蚀性能的影响

获取原文
获取原文并翻译 | 示例
       

摘要

X80 steel exhibits two different steady states in 0.5 mol L-1 NaHCO3 + 0.25 mol L-1 Na2CO3 solution with and without precathodic polarisation, which are activation and passivation respectively. Different amplitudes of alternating voltages were superimposed to the pre- and non-prepolarised steels. The results demonstrated that passivation of the non-prepolarised steel was enhanced by low amplitude alternating voltages but was destroyed by high amplitude alternating voltages. Moreover, the corrosion of the prepolarised steel was worsened with the application of alternating voltages.
机译:X80钢在0.5 mol L-1 NaHCO3 + 0.25 mol L-1 Na2CO3溶液中,在有和没有阴极极化的情况下,表现出两种不同的稳态,分别是活化和钝化。将不同幅度的交流电压叠加到预极化和非预极化钢上。结果表明,低振幅交流电压可增强非预极化钢的钝化,但高振幅交流电压可破坏钝化。而且,施加交流电压会加剧预极化钢的腐蚀。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号