...
首页> 外文期刊>Pferdeheilkunde >Evaluation of three portable lactate-measurement devices in exercising horses
【24h】

Evaluation of three portable lactate-measurement devices in exercising horses

机译:三种便携式乳酸测量装置的运动

获取原文
获取原文并翻译 | 示例
           

摘要

Since one of the validated handheld lactate (LA) measurement devices (Lactate Pro) is now out of production, an alternative instrument is to be found for equine exercise testing in the field and for use in horses with gastrointestinal disorders. The aim of this study was to evaluate three handheld LA analysers (Lactate Pro, Lactate Pro-2 and StatStrip Lactate Xpress), and to compare these with the gold standard laboratory assay (Lab-LA; DXC-600 Analyser - Beckman Coulterlab). A total of 215 blood samples were collected from the jugular vein of 44 eventing horses during standardized exercise testing. Immediately after collection each blood sample was parallel tested using the three lactate analysers. The rest of each blood sample was placed in NaF tubes and centrifuged within 8 hours. The plasma was stored at -20 degrees C for laboratory assay. The results of each analyser were compared with the laboratory analyser. All data were statistically evaluated using a linear mixed effect model (Akaike's Information criterion; t >2.00) and Partial Pearson correlations. The Partial Pearson correlations between Lab-LA and Lactate Pro, Lactate Pro-2 and StatStrip Lactate X-press were 0.974, 0.981, and 0.828 respectively. Of the three instruments the Lactate Pro-2 provided the closest correlation with the laboratory assay. The predicted values were derived from the formula: log (Lab-LA) = 0.27175 divided by 0.94567*(Lactate Pro-2) or Lab-LA = 1.3226*(Lactate Pro-2)0.94567. The predicted value for Lab-LA values using the Lactate Pro-2 was 0.992 for an average horse. The Lactate Pro-2 proved to be a good alternative for the Lactate Pro that is now no longer in production.
机译:由于验证的手持式乳酸(LA)测量装置(Lactate Pro)中的一项现已退出生产,因此可以找到替代仪器用于现场的马运动测试和用于胃肠道疾病的马匹。本研究的目的是评估三种手持式LA分析仪(乳酸Pro,乳酸Pro-2和Statstrip乳酸Xpress),并将其与金标准实验室测定进行比较(Lab-La; DXC-600分析仪 - Beckman Coulterlab)。在标准化运动测试期间,从颈静脉中收集了215个血液样品的腮术静脉。在收集后立即使用三个乳酸分析仪进行平行试验。将每个血液样品的其余部分置于NAF管中并在8小时内离心。将血浆储存在-20℃下进行实验室测定。将每个分析仪的结果与实验室分析仪进行比较。所有数据使用线性混合效果模型(Akaike的信息标准; T> 2.00)和部分Pearson相关性进行统计评估。 Lab-La和乳酸乳酸乳酸乳酸乳酸乳酸乳酸乳酸乳酸乳酸乳酸乳酸乳酸乳酸乳酸X型压机分别为0.974,0.981和0.828。在三个仪器中,乳酸Pro-2提供了与实验室测定最近的相关性。预测值衍生自公式:LOG(Lab-La)= 0.27175除以0.94567 *(乳酸PRO-2)或Lab-La = 1.3226 *(乳酸Pro-2)0.94567。使用乳酸Pro-2的Lab-La值的预测值为普通马为0.992。乳酸Pro-2证明是现在不再生产的乳酸乳酸乳酸的替代品。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号