首页> 外文期刊>Pediatric cardiology >Feasibility of Non-invasive Fetal Electrocardiographic Interval Measurement in the Outpatient Clinical Setting
【24h】

Feasibility of Non-invasive Fetal Electrocardiographic Interval Measurement in the Outpatient Clinical Setting

机译:门诊临床环境中无侵袭性胎儿心电图间隔测量的可行性

获取原文
获取原文并翻译 | 示例

摘要

Non-invasive fetal electrocardiography (ECG) is a promising method for evaluating fetal cardiac electrical activity. Despite advances in fetal ECG technology, its ability to provide reliable, interpretable results in a typical outpatient fetal cardiology setting remains unclear. We sought to determine the feasibility of measuring standard ECG intervals in an outpatient fetal cardiology practice using an abdominal fetal ECG device that employs blind source separation with reference, an innovative signal-processing technique for fetal ECG extraction. Women scheduled for clinically indicated outpatient fetal echocardiogram underwent 10 min of fetal ECG acquisition from the maternal abdomen using specialized gel electrodes. A bedside laptop computer performed fetal ECG extraction, allowing real-time visualization of fetal and maternal ECG signals. Offline post-processing of 1 min of recorded data yielded fetal P-wave duration, PR interval, QRS duration, RR interval, QT interval, and QTc. Fifty-five fetuses were studied with gestational age 18-37 weeks, including 13 with abnormal fetal echocardiogram findings and three sets of twins. Interpretable results were obtained in 91% of fetuses, including 85% during the vernix period and 100% of twin fetuses. PR interval and RR interval of 18-24 week gestation fetuses were significantly shorter than those with gestational age 25-31 and 32-37 weeks. Of the six fetuses with abnormal rhythms on fetal echocardiogram, fetal ECG tracing was interpretable in five and matched the rhythm noted on fetal echocardiogram. Abdominal fetal ECG acquisition is feasible for arrhythmia detection and ECG interval calculation in a routine clinical setting.
机译:非侵入性胎儿心电图(ECG)是评估胎儿心脏电活动的有希望的方法。尽管胎儿ECG技术的进步,但其在典型的门诊胎儿心脏病学环境中提供可靠,可解释结果的能力仍不清楚。我们试图确定使用盲源分离的腹部胎儿ECG装置测量门诊胎儿心脏病学实践中测量标准ECG间隔的可行性,该胎儿ECG装置是一种用于胎儿ECG提取的创新信号处理技术。妇女预定用于临床指示的门诊胎儿超声心动图,使用专用凝胶电极从母体腹部获取10分钟的胎儿ECG获取。床头笔记本电脑执行胎儿ECG提取,允许实时可视化胎儿和母体ECG信号。脱机后处理1分钟的记录数据产生胎儿p波持续时间,PR间隔,QRS持续时间,RR间隔,QT间隔和QTC。在18-37周内使用妊娠年龄的胎儿进行五十五胎儿,其中胎儿超声心动造型表发现13岁和三组双胞胎。可解释的结果是在91%的胎儿中获得,包括85%期间,在vernix期间和100%的双胎儿。 Pr间隔和18-24周的妊娠胎儿的妊娠胎儿明显短于妊娠年龄25-31和32-37周的胎儿。在胎儿超声心动图中具有异常节律的六个胎儿中,胎儿ECG追踪在五个中可解释,并匹配胎儿超声心动图的节奏。腹部胎儿ECG采集是在常规临床环境中的心律失常检测和ECG间隔计算的可行性。

著录项

  • 来源
    《Pediatric cardiology》 |2019年第6期|共8页
  • 作者单位

    Childrens Natl Hlth Syst Div Cardiol 111 Michigan Ave NW Washington DC 20010 USA;

    Childrens Natl Hlth Syst Sheikh Zayed Inst Pediat Surg Innovat 111 Michigan Ave NW Washington;

    Childrens Natl Hlth Syst Sheikh Zayed Inst Pediat Surg Innovat 111 Michigan Ave NW Washington;

    Childrens Natl Hlth Syst Div Cardiol 111 Michigan Ave NW Washington DC 20010 USA;

    Tohoku Univ Adv Interdisciplinary Biomed Engn Sch Med Aoba Ku 2-1 Seiryo Machi Sendai Miyagi;

    Tohoku Univ Adv Interdisciplinary Biomed Engn Sch Med Aoba Ku 2-1 Seiryo Machi Sendai Miyagi;

    Khalifa Univ Sci &

    Technol Dept Biomed Engn POB 127788 Abu Dhabi U Arab Emirates;

    Childrens Natl Hlth Syst Div Cardiol 111 Michigan Ave NW Washington DC 20010 USA;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 儿科学;
  • 关键词

    Fetal; Arrhythmia; Electrocardiogram; Prenatal;

    机译:胎儿;心律失常;心电图;产前;