首页> 外文期刊>Sleep >The KickStrip: a novel testing device for periodic limb movement disorder.
【24h】

The KickStrip: a novel testing device for periodic limb movement disorder.

机译:Kickstrip:一种用于周期性肢体运动障碍的新型测试装置。

获取原文
获取原文并翻译 | 示例
           

摘要

STUDY OBJECTIVES: In light of the ongoing debate over the clinical significance of periodic limb movement disorder (PLMD) and its monitoring in overnight sleep studies, we introduce a novel, portable, low-cost device for PLMD testing. The KickStrip is a disposable device, which includes a movement sensor, a central processing unit with real-time software, and a display. In the present study, the KickStrip final score (Kscore) is validated against the traditional periodic limb movement index (PLMI) based on overnight recordings in the sleep laboratory. DEISGN: Patients underwent full polysomnographic recordings concomitantly with the use of the KickStrip for a single night. SETTING: Sleep Disorders Unit at Loewenstein Rehabilitation Hospital and Sleep Medicine Center at Rambam Medical Center, Israel. PATIENTS: Eighty-two patients referred for overnight sleep recordings due to sleep disturbance of any kind. INTERVENTIONS: N/A. MEASUREMENTS AND RESULTS: The Kscores were collected and the PLMI computed foreach leg separately. Pearson correlations between Kscores and PLMI ranged between r = 0.83 to r = 0.88 (p < 0.001). Sensitivity and specificity values of the Kscores for increasing PLMD thresholds showed sensitivity ranging from 50% to 100% and specificity ranging from 83% to 100%. Receiver operating characteristic curves showed area-under-the-curve values ranging from 82% to 92%. Bland-Altman plot showed high agreement between the methods. CONCLUSIONS: Comparisons between the Kscores and the traditional PLMI show increased accuracy with severity level and excellent agreement. The KickStrip is a valuable tool for PLMD testing for both clinical and research purposes.
机译:研究目标:根据对周期肢体运动障碍(PLMD)的临床意义的持续辩论及其在隔夜睡眠研究中的监测,我们引入了一种用于PLMD测试的新型,便携式低成本的装置。 Kickstrip是一种一次性设备,其包括移动传感器,具有实时软件的中央处理单元和显示器。在本研究中,基于睡眠实验室的过夜录制,对传统的周期性肢体运动指数(PLMI)验证了Kickstrip终值(Kscore)。 Deisgn:患者接受了全面的多仪表记录,同时使用kickstrip一晚。环境:睡眠障碍单位在以色列Rambam Medical Centre的Loewenstein康复医院和睡眠医学中心。患者:八十二名患者引用过夜睡眠录音,因为任何类型的睡眠障碍。干预:n / a。测量和结果:收集Kscores,并分别计算PLMI计算的Foreach腿。 Kscores和PLMI之间的Pearson相关性在r = 0.83至r = 0.88之间(p <0.001)。用于增加PLMD阈值的Kscores的敏感性和特异性值显示敏感性范围为50%至100%,特异性范围为83%至100%。接收器操作特性曲线显示出区域下的曲线值,范围为82%至92%。 Bland-Altman Plot在这些方法之间表现出高协议。结论:KScores与传统PLMI之间的比较显示了严重程度和良好协议的准确性。 Kickstrip是临床和研究目的的PLMD测试的宝贵工具。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号