...
首页> 外文期刊>PACE: Pacing and clinical electrophysiology >Isolation of pulmonary veins using a thermoreactive implantable device with external energy transfer: Evaluation in a porcine model
【24h】

Isolation of pulmonary veins using a thermoreactive implantable device with external energy transfer: Evaluation in a porcine model

机译:用外部能量转移使用热反应性植入装置隔离肺静脉:猪模型中的评估

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Abstract Background Pulmonary vein isolation (PVI) is a well‐established method for the treatment of symptomatic paroxysmal atrial fibrillation, but is only partly successful with a high rate of electrical reconnection. We introduce a novel technique in which PVI is accomplished by noninvasive heating of a dedicated thermoresponse implant inserted into the pulmonary veins (PV), demonstrated in a porcine model. Methods A self‐expanding nitinol‐based implant was positioned in the common inferior PV of 11 pigs, using a fluoroscopy‐guided transatrial appendage approach. Ablation was performed through contactless energy transfer from a primary extracorporal coil to a secondary heat ring (HR) embedded in the proximal part of the implant. Electrophysiological conduction was assessed prior to and postablation, and at 3 months. Histological samples were obtained acutely (n??=??4) and after 3 months (n??=??7). Results In total, 13 PV implants were successfully positioned in the inferior PVs of 11 animals. Ablation was performed without injury of adjacent structures. PVI and bidirectional block was electrophysiologically confirmed in all cases immediately at the time of implantation and 3 months later in seven chronic animals in whom testing was repeated. Marked evidence of ablation around the proximal HR was evident at 3 months postprocedure, with scar tissue formation and only mild neointimal proliferation. Conclusions Successful PVI can be obtained by external electromagnetic heat transfer to a novel pulmonary vein implant.
机译:摘要背景技术肺静脉隔离(PVI)是治疗症状阵发性心房颤动的良好方法,但仅具有高速率的电重新连接。我们介绍一种新颖的技术,其中PVI通过插入肺静脉(PV)中的专用热响应植入物而完成PVI,在猪模型中证明。方法使用透视引导的跨性阑尾附录方法,将自扩张的镍钛基植入物定位在11只猪的常见下PV。通过从初级体内线圈的非接触能量转移到嵌入在植入物的近端部分的二次热环(HR)中进行消融。在关键和后,在3个月之前评估电生理传导。组织学样品急性地(n ?? =Δ?4),3个月后(n ?? = ?? 7)。结果总共,13个PV植入物成功地定位在11只动物的劣质PV。在没有相邻结构的情况下进行烧蚀。 PVI和双向块在植入时立即在所有病例中进行电生理学证实,3个月后七个慢性动物重复测试。在近端人力资源周围的明显证据显示在后期3个月,瘢痕组织形成和仅温和的新内膜增殖。结论通过外部电磁热传递到新型肺静脉植入物可以获得成功的PVI。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号