首页> 外文期刊>Steel & Composite Structures: An International Journal >Deterioration in strength of studs based on two-parameter fatigue failure criterion
【24h】

Deterioration in strength of studs based on two-parameter fatigue failure criterion

机译:基于双参数疲劳故障标准的螺柱强度劣化

获取原文
获取原文并翻译 | 示例
           

摘要

In the concept of two-parameter fatigue failure criterion, the material fatigue failure is determined by the damage degree and the current stress level. Based on this viewpoint, a residual strength degradation model for stud shear connectors under fatigue loads is proposed in this study. First, existing residual strength degradation models and test data are summarized. Next, three series of 11 push-out specimen tests according to the standard push-out test method in Eurocode-4 are performed: the static strength test, the fatigue endurance test and the residual strength test. By introducing the "two-parameter fatigue failure criterion," a residual strength calculation model after cyclic loading is derived, considering the nonlinear fatigue damage and the current stress condition. The parameters are achieved by fitting the data from this study and some literature data. Finally, through verification using several literature reports, the results show that the model can better describe the strength degradation law of stud connectors.
机译:在双参数疲劳失效标准的概念中,材料疲劳失效由损伤程度和当前应力水平决定。基于该观点,在该研究中提出了疲劳负荷下螺旋剪切连接器的残余强度降解模型。首先,总结了现有的残余强度劣化模型和测试数据。接下来,执行根据欧洲码-4中标准推出试验方法的三种推出样本试验:静态强度试验,疲劳耐久性测试和残余强度试验。通过引入“双参数疲劳失效准则”,循环加载后的残余强度计算模型,考虑到非线性疲劳损坏和电流应力条件。通过拟合来自该研究的数据和一些文献数据来实现参数。最后,通过使用多个文献报告的验证,结果表明,该模型可以更好地描述螺柱连接器的强度降级规律。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号