Background Measurements of transepidermal water loss (TEWL) and stratum corneum (SC) hydration are important for assessing epidermal functions. However, the availability of reliable and user-friendly devices, which can simultaneously measure both TEWL and SC hydration and can allow health providers to remotely access data in time, is limited. Materials and Methods GPSkin Barrier((R)) was compared with MPA5 system in the measurements of TEWL and SC hydration on the cheek, the dorsal hand, and the forearm in 200 normal volunteers, including 126 females and 74 males, aged 1-78 years with an average age of 45.24 +/- 1.04 years. Correlation of data measured with MPA5 system and GPSkin Barrier((R)) was determined. Results Levels of both TEWL and SC hydration measured with the Barrie GPSkin Barrier((R)) were lower than that with MPA5 system on all 3 body sites except for hydration on the cheek. The levels of both TEWL and SC hydration measured with GpSkin Barrier((R)) were correlated well with that measured with MPA5 system on all 3 body sites Conclusions GPSkin Barrier((R)) is a reliable, affordable, and versatile device for assessing epidermal permeability barrier function and SC hydration.
机译:Transepidermal水损失(TEWL)和Stratum Corneum(SC)水合的背景测量对于评估表皮功能是重要的。然而,可靠和用户友好的设备的可用性,可以同时测量TEWL和SC水合,并且可以允许健康提供者及时远程访问数据,有限。将GPSkin屏障((r))与MPA5系统进行比较,在脸颊,背部手和前臂上测量TEWL和SC水合的MPA5系统进行比较,其中200名正常志愿者,包括126名女性和74名男性,1-78岁年平均年龄为45.24 +/- 1.04岁。测定用MPA5系统和GPSkin屏障((R))测量的数据的相关性。结果用巴肯盖金屏障((r))测量的TEWL和SC水合的水平低于所有3个身体部位的MPA5系统,除了脸颊上的水化。用GPSkin屏障((R))测量的TEWL和SC水合水平良好,用MPA5系统在所有3个身体部位的结论结论GPSP屏障((R))是一种可靠的,价格合理和多功能的评估装置表皮渗透性屏障功能和SC水合。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号