Today, sizing HVAC systems plays an important role in the building design process, requiring an accurate method in order to avoid problems from over- or under-sized systems. To date, there have been five peak cooling load methods published by ASHRAE, including: the Total Equivalent Temperature Difference/Time Averaging Method, the Transfer Function Method, the Cooling Load Temperature Difference/Solar Cooling Load/Cooling Load Factor Method, the Heat Balance Method, and the Radiant Time Series Method. This study provides a thorough review of the five methods with respect to their history and summarizes the method differences that can lead to inaccurate sensible cooling load calculations.
机译:如今,Size HVAC系统在建筑设计过程中起着重要作用,需要准确的方法,以避免来自超尺寸的系统的问题。 迄今为止,Ashrae发布了五种峰冷却载荷方法,包括:总等效温差/时间平均方法,传递函数方法,冷却负载温度差/太阳能冷却负载/冷却负载因子方法,热平衡 方法,辐射时间序列方法。 本研究规定了对其历史的五种方法进行了彻底的审查,并总结了可能导致不准确的清洁载荷计算的方法差异。