首页> 外文期刊>Orthopedics >Radiographic Underestimation of In Vivo Cup Coverage Provided by Total Hip Arthroplasty for Dysplasia
【24h】

Radiographic Underestimation of In Vivo Cup Coverage Provided by Total Hip Arthroplasty for Dysplasia

机译:射线照相低估了由总髋关节置换术提供的体内杯覆盖物用于发育不良

获取原文
获取原文并翻译 | 示例
       

摘要

The accuracy of using 2-dimensional anteroposterior pelvic radiography to assess acetabular cup coverage among patients with developmental dysplasia of the hip after total hip arthroplasty (THA) remains unclear in retrospective clinical studies. A group of 20 patients with developmental dysplasia of the hip (20 hips) underwent cementless THA. During surgery but after acetabular reconstruction, bone wax was pressed onto the uncovered surface of the acetabular cup. A surface model of the bone wax was generated with 3-dimensional scanning. The percentage of the acetabular cup that was covered by intact host acetabular bone in vivo was calculated with modeling software. Acetabular cup coverage also was determined from a postoperative supine anteroposterior pelvic radiograph. The height of the hip center (distance from the center of the femoral head perpendicular to the inter-teardrop line) also was determined from radiographs. Radiographic cup coverage was a mean of 6.93% (SD, 2.47%) lower than in vivo cup coverage for these 20 patients with developmental dysplasia of the hip (P.001). However, both methods yielded highly correlated measurements for cup coverage (Pearson r=0.761, P.001). The size of the acetabular cup (P=.001) but not the position of the hip center (high vs normal) was significantly associated with the difference between radiographic and in vivo cup coverage. Two-dimensional radiographically determined cup coverage conservatively reflects in vivo cup coverage and remains an important index (taking 7% underestimation errors and the effect of greater underestimation of larger cup size into account) for assessing the stability of the cup and monitoring for adequate ingrowth of bone.
机译:使用二维前后骨盆放射照相的准确性评估髋关节关节成形术(THA)在髋关节置换术后(THA)后髋关节发育不良患者患者的髋关节杯覆盖仍不清楚。一组20例患有髋关节(20髋)的发育不良患者的患者接受了无硬粘土的THA。在手术过程中,但在髋臼重建后,将骨蜡压在髋臼杯的未覆盖表面上。用三维扫描产生骨蜡的表面模型。用模拟软件计算由Vivo中的完整宿主髋臼骨覆盖的髋臼杯的百分比。髋臼杯覆盖率也从术后仰卧过期前期骨盆射线照片中确定。从射线照片中确定了臀部中心的高度(距离泪珠垂直于泪珠的中心)。射线照相杯覆盖率的平均值低于这些20例髋关节发育不良患者的体内杯覆盖率为6.93%(SD,2.47%)(P& .001)。然而,两种方法都产生了对杯覆盖率的高度相关的测量(Pearson r = 0.761,P& .001)。髋臼杯的尺寸(p = .001)但不是髋关节中心(高Vs Normal)的位置与射线照相和体内杯覆盖之间的差异显着相关。二维放射线测定的杯覆盖保守地反映体内杯覆盖范围,仍然是一个重要指标(考虑更大的杯子大小的7%低估的效果和更大低估的效果)用于评估杯子的稳定性和适当的发起的监测骨。

著录项

  • 来源
    《Orthopedics》 |2018年第1期|共6页
  • 作者单位

    Sichuan Univ West China Hosp W China Med Sch Dept Orthoped Surg 37 Wainan Guoxue Rd Chengdu;

    Sichuan Univ West China Hosp W China Med Sch Dept Orthoped Surg 37 Wainan Guoxue Rd Chengdu;

    Sichuan Univ West China Hosp W China Med Sch Dept Orthoped Surg 37 Wainan Guoxue Rd Chengdu;

    Sichuan Univ West China Hosp W China Med Sch Dept Orthoped Surg 37 Wainan Guoxue Rd Chengdu;

    Duke Univ Sch Med Duke Mol Physiol Inst Durham NC USA;

    Sichuan Univ West China Hosp W China Med Sch Dept Orthoped Surg 37 Wainan Guoxue Rd Chengdu;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 骨科学(运动系疾病、矫形外科学);
  • 关键词

  • 入库时间 2022-08-20 05:26:55

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号