...
首页> 外文期刊>Orbit >Imaging of proximal lacrimal system with time domain anterior segment optical coherence tomography in Asian Indian population
【24h】

Imaging of proximal lacrimal system with time domain anterior segment optical coherence tomography in Asian Indian population

机译:亚洲印度人口时域前段光学相干断层扫描的近端泪道系统的成像

获取原文
获取原文并翻译 | 示例
           

摘要

This article reports proximal lacrimal system parameters using Anterior Segment Optical Coherence Tomography (ASOCT-Visante) in an apparently normal Asian Indian population with assessment of any correlation between tear meniscus height and punctal diameter. This was a prospectively designed observational study that included healthy adults, who volunteered for optical coherence tomography imaging (OCT) of their proximal lacrimal system. Time domain ASOCT (Visante) images of the punctum and proximal canaliculus were captured using the high resolution corneal scan protocol. External lacrimal punctal diameter (ELP), internal lacrimal punctal diameter (ILP), vertical canalicular length (VCL) and tear meniscus height (TMH) were calculated. Statistical analysis was performed using Pearson’s correlation test. Our study had 100 normal subjects with mean age 24.14 years, range 15–38 years. ASOCT (Visante) with advantage of deeper penetration was able to image canaliculus in all cases. The mean TMH, ELP, ILP and VCL was 252.7 ± 67.98 μm, 382.2 ± 103.14μm, 140.7 ± 67.29 μm and 811.8 ± 253.7 μm, respectively, in 100 normal subjects. No correlation was found between ELP, ILP and TMH (Pearson’s Correlation; r = -0.355, p > 0.05 for all). ASOCT (VisanteTM) is a non-invasive and easy to use objective tool for imaging proximal lacrimal system. Further studies are required to validate normative data and correlate with microscopic findings of lacrimal system.
机译:本文在明显正常的亚洲印度人口中报告了使用前段光学相干断层扫描(ASOCT-Visante)的近端曲曲线系统参数,评估了泪弯液体高度和尖端直径之间的任何相关性。这是一项前瞻性地设计的观察研究,包括健康成年人,他们为其近端泪流的系统进行了光学相干断层扫描成像(OCT)。使用高分辨率的角膜扫描协议捕获尖端和近端CANALICULUS的时域ASOCT(Visante)图像。计算外泪 - 泪 - 直径(ELP),内部泪排血尖直径(ILP),垂直穴位长度(VCL)和泪液弯腰高度(TMH)。使用Pearson的相关试验进行统计分析。我们的研究有100名正常科目,平均24.14岁,范围为15-38岁。 ASOCT(Visante)具有更深渗透性的优势,能够在所有情况下进行图像穴位。平均TMH,ELP,ILP和VCL分别为252.7±67.98μm,382.2±103.14μm,140.7±67.29μm和811.8±253.7μm,在100个正常受试者中。在ELP,ILP和TMH之间没有发现相关性(Pearson的相关性; r = -0.355,全部p> 0.05)。 ASOCT(Visantetm)是一种非侵入性且易于使用的用于成像近端泪流的系统的客观工具。需要进一步的研究来验证规范数据并与泪腺系统的微观结果相关。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号