首页> 外文期刊>Aerosol Science and Technology: The Journal of the American Association for Aerosol Research >The Development and Designation Testing of a New USEPA-Approved Fine Particle Inlet:A Study of the USEPA Designation Process
【24h】

The Development and Designation Testing of a New USEPA-Approved Fine Particle Inlet:A Study of the USEPA Designation Process

机译:一种新的USEPA批准的细颗粒入口的开发和设计测试:关于USEPA指定过程的研究

获取原文
获取原文并翻译 | 示例

摘要

This article discusses the practical challenge of meeting USEPA requirements for equivalency between novel particulate matter monitoring instruments and the USEPA WINS PM_(2.5) Impactor (i.e.,the Federal Reference Method sampler for fine particulate matter).A project was undertaken to develop a new PM_(2.5) instrument in which the WINS impactor was substituted by a cyclone,to give superior performance over long sampling periods under heavy loading.Empirical cyclone models were used to develop a new generation of very sharp cut cyclones (VSCC),together with a particular VSCC specimen suited to PM_(2.5) sampling at 16.67 min~(-1).In laboratory tests,this VSCC demonstrated a precise 2.5 mum D_(50) cutpoint and sharpness as good as the WINS.A formal application was then undertaken to achieve USEPA Class II Equivalency designation.The process included aerosol laboratory loading trials,with results showing no change in cutpoint after up to 90 days between cleaning cycles.Field trials to compare the VSCC to the WINS FRM were then performed in both western and eastern air sheds to demonstrate the precision and accuracy of the candidate VSCC FEM.The results showed that the VSCC instrument yielded precision and accuracy within USEPA requirements,although the USEPA data requirements for the field trials (in terms of aerosol size distribution and concentration) were not fully met.The outcome of the project was that the Class II equivalency designation was achieved,but not without major difficulties in gathering suitable and sufficient data to meet the stringent test requirements laid down by USEPA.Some changes in the designation procedure are recommended in light of this experience.
机译:本文讨论了在新颗粒物监测仪器和USEPA WINS PM_(2.5)撞击器(即用于细颗粒物的联邦参考方法采样器)之间达到美国环保局要求的等效性的实际挑战。进行了一个开发新PM_的项目。 (2.5)用WINS撞击器替换为旋风分离器的仪器,可在重载下长时间采样期间提供出色的性能。经验性旋风分离器模型用于开发新一代的非常锋利的旋风分离器(VSCC),以及VSCC标本适合在16.67 min〜(-1)的PM_(2.5)采样。在实验室测试中,此VSCC展示了精确的2.5毫米D_(50)切割点和锐度,与WINS一样好。美国环保局(USEPA)II级等效标志。该过程包括实验室进行气雾剂加载试验,结果表明在两次清洁周期之间长达90天后,临界点没有变化。然后在西方和东部的飞机棚中进行了VSCC到WINS FRM的试验,以证明候选VSCC FEM的精度和准确性。结果表明VSCC仪器在USEPA要求范围内产生了精度和准确度,尽管USEPA数据要求该项目的结果是达到了II类等效性的标准,但是在收集合适且足够的数据以满足严格的测试要求方面也没有很大的困难。根据这种经验,建议对指定程序进行一些更改。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号