Laboratory and Field Tests of a Novel Three-Stage Personal Dust Sampler for Sampling Three Dust Fractions Simultaneously

机译:新型三阶段个人粉尘采样器同时采样三个粉尘组分的实验室和现场测试

获取原文
获取原文并翻译 | 示例
       

摘要

This study designed and calibrated a novel three-stage personal dust sampler for sampling inhalable, thoracic, and respirable dust fractions simultaneously. The sampler has an annular inlet as the first stage for inhalable dust sampling, two impactors in the second and third stages to classify thoracic and respirable dusts, respectively, and a final filter. Laboratory calibration tests using monodis-perse liquid and solid particles showed that with 100 ppi (pores per inch) PUF (porous polyurethane foam) substrates and at the flow rate of 3.2 L/min, the sampling efficiency curves of both impactor stages matched with the ISO/CEN/ACGIH thoracic and respirable sampling criteria, respectively. The sampler also agreed with the inhalable criterion for particles smaller than 17 μm while the deviation increases with increasing particle diameter with a maximum of 28% for 27 μm particles. It was also found that collection efficiency curve for solid particles was similar to that of liquid particles, indicating that there was no solid particle bounce from the PUF substrates for both impactors. This study also compared inhalable, thoracic, and respirable dust concentrations measured by the present three-stage personal dust samplers with those of the Respicon samplers at three different workplaces. Without using a correction factor of 1.5 for the extrathoracic dusts of the Respicon, field results showed that the present three-stage sampler measured three dust fractions comparable to those of the Respicon samplers. The inhalable dust concentrations of the two samplers differed within 5% while the thoracic and respirable concentration differed by less than 22%.
机译:这项研究设计并校准了一种新颖的三级个人粉尘采样器,用于同时采样可吸入,胸部和可吸入粉尘的采样。采样器有一个环形进气口,作为可吸入灰尘采样的第一阶段,第二和第三阶段有两个撞击器,分别对胸腔和可吸入的灰尘进行分类,最后还有一个过滤器。使用单分散液体和固体颗粒的实验室校准测试表明,对于100 ppi(孔/英寸)PUF(多孔聚氨酯泡沫)基材,流速为3.2 L / min,两个撞击器级的采样效率曲线与分别采用ISO / CEN / ACGIH胸腔和可呼吸采样标准。采样器还同意小于17μm的颗粒的可吸入标准,而偏差随粒径的增加而增加,对于27μm的颗粒,最大偏差为28%。还发现固体颗粒的收集效率曲线类似于液体颗粒的收集效率曲线,这表明对于两个撞击器,PUF基底均没有固体颗粒反弹。这项研究还比较了目前的三阶段个人粉尘采样器与Respicon采样器在三个不同工作场所所测得的可吸入,胸部和可吸入粉尘浓度。对于Respicon的胸外粉尘,如果不使用1.5的校正因子,则现场结果表明,当前的三级采样器测量的三个灰尘分数与Respicon采样器的相当。两个采样器的可吸入粉尘浓度差异在5%以内,而胸腔和可呼吸粉尘浓度的差异小于22%。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号