首页> 外文期刊>Microchemical Journal: Devoted to the Application of Microtechniques in all Branches of Science >Speciation analysis of thallium in tobaccos using liquid chromatography inductively coupled plasma mass spectrometry
【24h】

Speciation analysis of thallium in tobaccos using liquid chromatography inductively coupled plasma mass spectrometry

机译:液相色谱电感耦合等离子体质谱法使用液相色谱法铊铊的形态分析

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

An inductively coupled plasma mass spectrometer (ICP-MS) was used as a liquid chromatographic detector for the speciation analysis of thallium in tobacco and cigarette ash samples. In this study, ionic Tl species, namely Tl (I) and Tl(III) were well separated in less than 2 min by reversed-phase high performance liquid chromatography (RP-HPLC). The stationary and mobile phases were C8 column and 7 mmol L-1 tetrabutylammonium phosphate (TRAP), 6 mmol L-1 diethylenetriamine pentaacetic acid (DTPA) in 2% (v/v) methanol solution (pH 5) respectively. Effluent from the HPLC column was delivered to the nebulizer of the ICP-MS for the determination of Tl. Detection limit was 0.003 ng mL(-1) for both Tl(I) and Tl(III) compounds based on peak height. The relative standard deviation of peak areas for five injections of a mixture containing 1 ng TlmL(-1) each species was better than 1%. The Tl species were quantitatively leached from the tobacco and the ash into a solution of 5 mmol L-1 DTPA in 100 mmol L-1 ammonium acetate with/or without HF in an ultrasonic bath during a period of 20 min. The addition of HF improved the extraction of TI from the ash sample. The extraction efficiency of Tl from tobacco was in the range 98-110%. Speciation analysis by HPLC-ICP-MS on tobacco samples showed a satisfactory agreement with the total Tl concentration obtained by ICP-MS analysis of completely dissolved samples. Tl(I) was the only detectable Tl species in tobacco samples analyzed, however both Tl(I) and Tl(III) were present in the cigarette ash.
机译:电感耦合等离子体质谱仪(ICP-MS)用作液相色谱检测器,用于烟草和香烟灰样品中铊的形态分析。在该研究中,通过反相高效液相色谱(RP-HPLC)在小于2分钟的小于2分钟内,离子TL物种,即TL(I)和TL(III)在少于2分钟。静止和移动相是C8柱和7mmol L-1四丁基磷酸铵(捕获),分别为2%(v / v)甲醇溶液(pH5)的6mmol L-1二亚乙基三胺五乙酸(DTPA)。从HPLC柱的流出物递送到ICP-MS的雾化器中,用于测定T1。对于基于峰值高度的TL(I)和T1(III)化合物,检测限为0.003 ng ml(-1)。峰面积的五个注射含有1ng TLML(-1)每种物种的相对标准偏差优于1%。在20分钟内,从烟草和灰分中定量地从烟草和灰分中从烟草和灰分中浸出5mmol L-1 DTPA的溶液中,在超声波浴中,在超声浴中,在超声浴中。加入HF改善了从灰样品中提取Ti。从烟草的TL的提取效率在98-110%的范围内。 HPLC-ICP-MS在烟草样品上的形态分析表明,令人满意的协议与通过完全溶解样品的ICP-MS分析获得的总T1浓度。 T1(i)是分析的烟草样品中唯一可检测的T1种,但是T1(I)和T1(III)都存在于香烟灰中。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号