【24h】

Power measurement standards for high-power lasers: comparison between the NIST and the PTB

机译:高功率激光器的功率测量标准:NIST和PTB之间的比较

获取原文
获取原文并翻译 | 示例
           

摘要

We report the results of the first laser high-power measurement comparison between the Physikalisch-Technische Bundesanstalt (PTB, Germany), and the National Institute of Standards and Technology (NIST, USA). Laser power transfer standards were calibrated at both national standards laboratories between 82 W and 127 W at 1.06 μm and between 85 W and 554 W at 10.6 μm. Relative agreement between the standards of the two laboratories was demonstrated to lie between 5×10~(3) and 7×10~(-3), which is well within the combined uncertainties.
机译:我们报告了Physikalisch-Technische Bundesanstalt(PTB,德国)和国家标准与技术研究所(NIST,USA)之间的第一种激光大功率测量比较结果。 激光动力转移标准在82W和127W的国家标准实验室以1.06μm和10.6μm之间的82W和127W校准。 两位实验室标准之间的相对协议被证明是在5×10〜(3)和7×10〜(-3)之间,这在组合的不确定因素中。

著录项