首页> 外文期刊>Magnetic resonance in medicine: official journal of the Society of Magnetic Resonance in Medicine >Fast, precise, and accurate myocardial T 1 1 mapping using a radial MOLLI sequence with FLASH readout
【24h】

Fast, precise, and accurate myocardial T 1 1 mapping using a radial MOLLI sequence with FLASH readout

机译:使用具有闪存读数的径向Molli序列快速,精确,精确的心肌T 1 1映射

获取原文
获取原文并翻译 | 示例

摘要

Purpose Quantitative cardiac MRI, and more particularly T 1 mapping, has become a most important modality to characterize myocardial tissue. In this work, the value of a radial variant of the conventional modified Look‐Locker inversion recovery sequence (raMOLLI) is demonstrated. Methods The raMOLLI acquisition scheme consisted of five radial echo trains of 80 spokes acquired using either a fast low‐angle shot (FLASH) or a true fast imaging with steady‐state‐precession (TrueFISP) readout at different time points after a single magnetization inversion. View sharing combined with a compressed sensing algorithm allowed the reconstruction of 50 images along the T 1 relaxation recovery curve, to which a dictionary‐fitting approach was applied to estimate T 1 . The sequence was validated on a nine‐vial phantom, on 19 healthy subjects, and one patient suffering from dilated cardiomyopathy. Results The raMOLLI sequence allowed a significant decrease of myocardial T 1 map acquisition time down to five heartbeats, while exhibiting a higher degree of accuracy and a comparable precision on T 1 value estimation than the conventional modified Look‐Locker inversion recovery sequence. The FLASH readout demonstrated a better robustness to B 0 inhomogeneities than TrueFISP, and was therefore preferred for in vivo acquisitions. Conclusions This sequence represents a good candidate for ultrafast acquisition of myocardial T 1 maps. Magn Reson Med 79:1387–1398, 2018. ? 2017 International Society for Magnetic Resonance in Medicine.
机译:目的是定量心脏MRI,更具体地是T 1映射,已成为表征心肌组织的最重要的态化。在这项工作中,证明了传统改进的外观储物柜反转恢复序列(ramolli)的径向变体的值。方法采集方案由使用快速低角度拍摄(闪光灯)的80个辐条的五个径向回声列组成,或在单个磁化反转之后在不同时间点处获得具有稳态出版(TrueFisp)读数的真正快速成像的80个辐条。视图共享结合压缩传感算法允许沿T 1松弛恢复曲线重建50张图像,其中拟字典拟合方法应用于估计T 1。该序列在19个小时的幻影上验证,19个健康受试者,以及患有扩张的心肌病的一名患者。结果ramolli序列允许显着降低心肌T 1地图采集时间下降到五个心跳,同时表现出比传统改进的外观锁定反演恢复序列更高的准确度和与T 1值估计的比较精度。闪存读数表明比Truefisp更好地对B 0不均匀性的鲁棒性,因此优选用于体内采集。结论该序列代表了超快获取心肌T 1地图的良好候选者。 Magn Reson Med 79:1387-1398,2018 2017年医学磁共振的国际社会。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号