首页> 外文期刊>Food analytical methods >Analysis of Endocrine-Disrupting Compounds from Cheese Samples Using Pressurized Liquid Extraction Combined with Dispersive Liquid-Liquid Microextraction Followed by High-Performance Liquid Chromatography
【24h】

Analysis of Endocrine-Disrupting Compounds from Cheese Samples Using Pressurized Liquid Extraction Combined with Dispersive Liquid-Liquid Microextraction Followed by High-Performance Liquid Chromatography

机译:使用加压液体萃取与分散液 - 液微萃取后的奶酪样品中的内分泌样品中断的化合物分析,然后高效液相色谱法

获取原文
获取原文并翻译 | 示例

摘要

Simultaneous extraction and preconcentration of five endocrine disrupting compounds including di-butyl phthalate, di-iso-nonyl phthalates, di-ethylhexyl phthalate, di-ethylhexyl adipate, and bisphenol A from cheese have been developed using pressurized liquid extraction combined with dispersive liquid-liquid extraction followed by high-performance liquid chromatography-diode array detector. In this method, initially, the analytes are extracted into a water-miscible extraction solvent (acetone) at high pressure (1000psi) and temperature (70 degrees C) in the presence of carbon tetrachloride as a modifier. After extraction, a volume of the organic phase is removed and dispersed into deionized water. The cloudy solution was centrifuged, and the sedimented phase is used in analysis. Efficient parameters were optimized using one-parameter-at-one-time strategy, and low limits of detection and quantification in the ranges of 0.82-3.1 and 2.8-10ngg(-1) were obtained, respectively. Relative standard deviations lower than 8% show an acceptable precision for the present method. The enrichment factors and extraction recoveries in the ranges of 259-319 and 78-96% were achieved, respectively. Lastly, some real samples were analyzed and di-butyl phthalate and di-ethylhexyl phthalate were found in them.
机译:使用加压液体萃取与分散液 - 液组合开发了与邻苯二甲酸二丁酯,二乙醇酸酯,邻苯二甲酸酯,邻苯二甲酸二乙酸二乙酯,二乙基己基和双酚A的二乙基己酯,二乙基己基和双酚A的脱苯二甲酸酯的萃取和预浓缩。提取,然后高性能液相色谱 - 二极管阵列检测器。在该方法中,最初,将分析物在高压(1000psi)和温度(70℃)的水中萃取到水中的萃取溶剂(丙酮)中,在四氯化物作为改性剂存在下。萃取后,除去体积的有机相并将其分散到去离子水中。离心混浊的溶液,沉积相用于分析。使用单个参数 - 一次性策略优化有效参数,并分别获得0.82-3.1和2.8-10ngg(-1)范围的低检测和定量的低限制。低于8%的相对标准偏差显示了本方法的可接受的精度。富集因子和萃取回收率分别实现了259-319和78-96%的浓度。最后,分析了一些真实样品,并在它们中发现邻苯二甲酸酯和邻苯二甲酸二乙基己酯。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号