This study aims to measure ECG signals by the AgNW/PU nanoweb electrodes, and, to compare with signals measured by the conventional Ag/AgCl electrodes. Finally, to investigate the usage potential of the AgNW/PU nanoweb as ECG textile electrodes. The ECG textile electrodes were fabricated, using the polyurethane (PU) nanoweb (Pardam, s.r.o., Czech Republic) coated with 1 wt% of silver nanowires (AgNW) dispersed in ethanol (KLK Co., Korea). To measure the ECG signals, eight participants (Male:Female=1:1) were collected, and then, the signals were measured at rest-state and stress-state in anechoic chamber using Lead I method. From the measured ECG signals, heart rate (HR) and R-R intervals were acquired by using MP150 (Biopac system Inc., USA) and Acqknowledge (ver. 4.2, Biopac system Inc., USA), and then, analyzed by using Kubios HRV (ver. 2.0., Biosignal Analysis and Medical Imaging Group, Finland). To examine the morphology of the signals, direct visual evaluation was performed. Also, to statistically compare to the signals, Wilcoxon signed-rank test was conducted by using R statistical language and RStudio (1.0.143 ver., RStudio, Inc., USA). As a result, the ECG waveforms measured by the two different types of electrodes looked similar, especially, QRS-complex, P-wave and T-wave as well as R-peaks properly appeared. Also, there was not a significant difference of HR and RR-intervals measured by the two different types of electrodes. It demonstrated that the new AgNW/PU nanoweb electrodes could perform properly as ECG electrodes.
机译:该研究旨在通过AGNW / PU nanoweB电极测量ECG信号,并且与传统AG / AGCL电极测量的信号进行比较。最后,研究AGNW / PU NANOWEB作为ECG纺织电极的使用电位。使用聚氨酯(PU)Nanoweb(Pardam,S.R.O.,捷克共和国)制造ECG纺织电极,涂有1wt%的银纳米线(AgNW)分散在乙醇(KLK Co.,Korea)中。为了测量ECG信号,收集八个参与者(男性:雌性= 1:1),然后,使用引线I方法在AneChice室中的静态和应力状态测量信号。通过使用MP150(BioPac System Inc.,USA)和Acqknowledge(Ver.4.2,BioPac System Inc.,USA)来获取心率(HR)和RR间隔,然后通过使用Kubios HRV进行分析(Ver。2.0。,生物病分析和医学成像组,芬兰)。为了检查信号的形态,进行直接视觉评估。此外,要与信号进行统计比较,通过使用R统计语言和Rstudio(1.0.143 ver。,Rstudio,Inc.,USA)进行Wilcoxon签名级别测试。结果,由两种不同类型的电极测量的ECG波形看起来类似,特别是QRS复合物,P波和T波以及正确出现的R峰。而且,通过两种不同类型的电极测量的HR和RR间隔没有显着差异。它表明,新的AGNW / PU Nanoweb电极可以正常地作为ECG电极进行。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号