Highlights ? Genium knee improves stair ascent gait for amputees relative to C-Leg. ? Genium did not significantly change gait for stair descent relative to C-Leg. ? Genium and C-Leg knees show significant differences relative to non-amputees. Abstract This study was a randomized crossover of stair ambulation of Transfemoral Amputees (TFAs) using the Genium and C-Leg prosthetic knees. TFAs typically have difficulty ascending and descending stairs, limiting community mobility. The objective of this study was to determine the relative efficacy of the Genium and C-Leg prostheses for stair ascent and descent, and their absolute efficacy relative to non-amputees. Twenty TFAs, and five non-amputees participated in the study. TFAs were randomized to begin the study with the Genium or C-Leg prosthesis. Informed consent was obtained from all participants prior to data collection and the study was listed on clinicaltrials.gov (#NCT01473662). After fitting, accommodation, and training, participants were asked to demonstrate their preferred gait pattern for stair ascent and descent and a step-over-step pattern if able. TFAs then switched prosthetic legs and repeated fitting, accommodation, training, and testing. An eight camera Vicon optical motion analysis system, and two AMTI force plates were used to track and analyze the participants’ gait patterns, knee flexion angles, knee moment normalized by body weight, and swing time. For stair descent, no significant differences were found between prostheses. For stair ascent, Genium use resulted in: increased ability to use a step-over-step gait pattern ( p = 0.03), increased prosthetic side peak knee flexion ( p 0.01), and increased swing duration ( p 0.01). Changes in contralateral side outcomes and in knee moment were not significant. Overall the Genium knee decreased deficiency in gait patterns for stair ascent relative to the C-Leg, by enabling gait patterns that more closely resembled non-amputees.
机译:强调 ? Geneium Knee改善了相对于C腿的阶段上升步态。还enerations在C-LEC中没有显着改变楼梯下降的步态。还基因砷和C腿部膝盖显示出相对于非患者的显着差异。摘要本研究是使用雷尼米和C腿假膝膝关节的转发汞(TFAS)的阶梯式气象的随机交叉。 TFA通常难以上升和下降楼梯,限制了社区移动性。本研究的目的是确定遗传率和C腿假体对楼梯上升和下降的相对疗效,以及相对于非患者的绝对疗效。二十个TFA和五个非禁止参加了这项研究。 TFAS随机地开始与雷尼酸或C腿假体进行研究。在数据收集之前的所有参与者获得知情同意,并在ClinicalTrials.gov上列出了该研究(#NCT01473662)。在拟合,住宿和培训之后,被要求参与者展示他们的首选步态模式,用于楼梯上升和下降,如果能够进行滞留阶梯模式。 TFA然后切换假肢腿和重复的拟合,住宿,培训和测试。八个相机VICON光学运动分析系统和两个AMTI力板用于跟踪和分析参与者的步态图案,膝关节屈曲角度,受体重标准化的膝盖矩和摇摆时间。对于楼梯下降,假体之间没有发现显着的差异。对于楼梯上升,灭毒灭菌导致:增加使用阶梯式步态图案的能力(P = 0.03),增加假肢侧峰膝关节(P 0.01),增强的摆动持续时间(p 0.01)。对侧侧外结果和膝关节的变化并不重要。总体而言,通过使步态模式能够更加类似于非正常的步态模式,总体上膝盖膝关节膝关节与C腿的步态模式的缺陷降低。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号