Highlights ? Transtibial pressure-cast sockets are an alternative to hand-cast designs. ? Participants wore both socket types and we compared the initial outcome measures. ? We analysed mobility, functional capacity, gait symmetry, comfort and preference. ? No significant differences in initial outcome measures were seen across the sockets. Abstract This study compared the physical function and comfort level of patients with unilateral transtibial amputation after being fitted with a hand-cast Patella Tendon Bearing (PTB) socket and a pressure-cast (PCAST) hydrocast socket. The latter technique aims to reduce the skill dependency currently required for socket manufacture and fit. The study was conducted at the Vietnamese Training Centre for Orthopaedic Technologies and involved seventeen Vietnamese participants with unilateral transtibial amputation, all of whom were long term users of prosthetics. All participants were fitted with two sockets manufactured using both hand-cast and PCAST techniques with International Committee of the Red Cross components. Walking tests (timed up and go test and six-minute-walk-test), spatio-temporal gait analyses and subjective comfort assessments were completed after a short acclimatisation period with each socket. The participant-preferred socket was also noted. No significant differences were found for the measures of mobility, functional capacity, spatio-temporal gait parameters, gait symmetry, perceived comfort or participant socket preference. The results show the initial patient outcomes are similar when participants are fitted with a hand-cast PTB socket and a PCAST hydrocast sockets. Future work should confirm these findings in a longer trial.
机译:强调 ?浇筑压力浇注插座是手工铸造设计的替代方案。还参与者穿着套接字类型,我们比较了初始结果措施。还我们分析了移动性,功能能力,步态对称,舒适和偏好。还在套接字上看到初始结果措施没有显着差异。摘要本研究比较了在铸造髌骨腱轴承(PTB)插座和压力浇注(PCAST​​)加热插座上的单侧串通截肢患者的物理功能和舒适程度。后一种技术旨在减少目前插座制造和适合所需的技能依赖性。该研究在越南矫形技术培训中心进行,并涉及十七位与单方面的打击截肢的参与者,所有这些都是假肢的长期用户。所有参与者都配备了两个插座,并使用手工铸造和PCAST​​技术制造,具有红十字会国际委员会。步行试验(定时和去测试和六分钟步行测试),几次使用每个插座的短期性适应期后完成时空步态分析和主观舒适评估。还注意到参与者的首选插座。没有发现迁移率,功能能力,时空步态参数,步态对称,感知舒适或参与者偏好的措施没有显着差异。结果表明,当参与者配有手工铸造PTB插座和PCAST​​加氢套接插座时,初始患者结果是相似的。未来的工作应在更长的审判中确认这些调查结果。

著录项

相似文献

  • 外文文献
  • 中文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号