首页> 外文期刊>Eye & contact lens >Comparative Evaluation of Use of 400-m and 350-m Microkeratome Head to Prepare Donor Tissue in Cases of Descemet Stripping Automated Endothelial Keratoplasty
【24h】

Comparative Evaluation of Use of 400-m and 350-m Microkeratome Head to Prepare Donor Tissue in Cases of Descemet Stripping Automated Endothelial Keratoplasty

机译:使用400m和350 m微孔孔头部使用的比较评价为Descemet汽提内皮角膜术病例中的供体组织制备供体组织

获取原文
获取原文并翻译 | 示例
           

摘要

Purpose:To compare the outcomes of 400-m microkeratome head with 350-m microkeratome head Descemet stripping automated endothelial keratoplasty (DSAEK) in a prospective comparative study.Methods:Twenty cases of pseudophakic bullous keratopathy were randomly allocated into two groups. Group 1 underwent slow, single-pass 400-m microkeratome head, whereas group 2 underwent the standard technique of DSAEK using a 350-m microkeratome head. The primary outcome measures were best-corrected visual acuity (BCVA) at 6 months.Results:Groups were comparable in baseline characteristics. The mean central graft thickness (GT) at 6 months in group 1 was significantly thinner than group 2 (90.4428.67 vs. 165.60 +/- 62.74 m; P=0.003). The BCVA and contrast sensitivity were significantly better in group 1 than in group 2 (BCVA: 0.34 +/- 0.15 vs. 0.53 +/- 0.19 logMAR units, P=0.02; contrast sensitivity: 1.48 +/- 0.13 vs. 1.06 +/- 0.22, P=0.001). A significant correlation was found between both postoperative BCVA and contrast sensitivity, with the postoperative GT using Spearman rho correlation analysis (R=0.534, P=0.01 for BCVA and R=-0.522, P=0.02 for contrast sensitivity). The percentage endothelial cell loss was comparable between the 2 groups at the last follow-up (P=0.3). No major complications were observed during the study period.Conclusions:The use of a 400-m microkeratome head instead of 350-m head can improve the visual outcomes in DSAEK without increasing the risk of complications. The thickness of the DSAEK graft can affect the visual acuity and contrast sensitivity.
机译:目的:将400米微型遥控头的结果与350米微立通道头Degemet剥离自动内皮角膜术(Dsaek)进行比较。方法:20例假畸形大疱性角膜病变被随机分配成两组。第1组接受慢速,单通过400米遥头部,而第2组使用350米的遥控头进行DSAEK的标准技术。主要结果措施在6个月内是最佳纠正的视力(BCVA)。结果:组在基线特征中具有可比性。第1组6个月的平均中央移植物厚度(GT)显着薄于2组(90.4428.67 vs.165.60 +/- 62.74 m; p = 0.003)。 BCVA和对比度敏感度在第1组中显着更好(BCVA:0.34 +/- 0.15与0.53 +/- 0.19 Logmar单位,P = 0.02;对比度灵敏度:1.48 +/- 0.13与1.06 + / - 0.22,p = 0.001)。在术后BCVA和对比度敏感性之间发现了显着的相关性,术后GT使用Spearman Rho相关性分析(R = 0.534,P = 0.01,对于BCVA和R = -0.522,P = 0.02,用于对比度敏感性)。内皮细胞损失的百分比与最后一次随访(P = 0.3)之间的2组之间相当。在研究期间没有观察到主要的并发症。结论:使用400 m微张母顶头而不是350 m头可以改善dsaek中的视觉结果,而不会增加并发症的风险。 DSAEK移植物的厚度可以影响视力和对比度灵敏度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号